Fireplace Installation - Superior DRL4543TEN Installation And Operation Instructions Manual

Direct-vent linear gas fireplace
Table of Contents

Advertisement

Propane/LP
Supply Tank
Figure 25 - External Regulator with Vent Pointing Down
(Propane/LP Only)
Check your building codes for any special requirements for locating
equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent
excess sealant from going into pipe. Excess sealant in pipe could
result in clogged fireplace valves.
WARNING: Use pipe joint sealant that is resistant
to liquid petroleum (LP) gas.
We recommend that you install a sediment trap/drip leg in supply line
as shown in Figure 26. Locate sediment trap/drip leg where it is within
reach for cleaning. Install in piping system between fuel supply and
fireplace. Locate sediment trap/drip leg where trapped matter is not
likely to freeze. A sediment trap traps moisture and contaminants.
This keeps them from going into fireplace gas controls. If sediment
trap/drip leg is not installed or is installed wrong, fireplace may not
run properly.
Gas Shutoff
Valve
1/2" NPT
Incoming
Gas Line
126718-01C
FIREPLACE INSTALLATION Continued
External Regulator
with Vent Pointing
Down
Flexible
Gas Line
Do NOT
Kink
Note:
1) Wire connections not
shown for clarity
2) * 1/8" NPT Plugged Tapping
Figure 27 - Connecting Incoming Gas Line to Flex Gas Line
Superiorfireplaces.US.com
Equipment Shutoff Valve
with 1/8" NPT Tap*
Approved
Flexible
Gas Line
3" Minimum
* The equipment shutoff valve may be sup-
plied with the appliance or you can purchase
it from your retailer.
CONNECTING FIREPLACE TO GAS SUPPLY
Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Sealant (resistant to propane/LP gas, not provided)
1. Route flexible gas line (provided by installer) from equipment
shutoff valve to fireplace. Route flexible gas supply line through
one of the access holes on side of fireplace.
2. Attach flexible gas line from gas supply to control valve (see Figure
27).
3. Check all gas connections for leaks. See Checking Gas Connec-
tions, page 22.
Inlet Pressure Tap
Outlet Pressure Tap
Natural - From
Gas Meter (5.5"
W.C. to 10.5" W.C.
Pressure)
Propane/LP From
External Regulator
(11" W.C. to 14"
W.C. Pressure)
Cap
Pipe
Tee
Joint
Nipple
Sediment Trap/
Drip Leg
Figure 26 - Gas Connection
Pilot Adjustment
Set Screw
21