GROUND FLOOR INSTALLATION
Recommended Applications:
• Through the wall using round or
square termination
(V) Vertical
Required
Minimum
Vertical Pipe
53"
1 ft.
65"
2 ft.
77"
3 ft.
V + H = 40 feet maximum
H = 20 feet maximum
Venting with Two 90° Elbows
Vertical (V) Horizontal (H
5' Min.
8' Max
6' Min.
10' Max
7' Min.
15' Max
20'Min.
20' Max
16
VENTING INSTALLATION Continued
V + 90· Elbow
(H) Horizontal
Maximum
7 ft.
11 ft.
20 ft.
Figure 14 - Horizontal Termination Using One 90° Elbow
+ H
)
1
2
Figure 15 - Horizontal Termination Using Two 90° Elbows
Superiorfireplaces.US.com
90° Elbow
1' Pipe Min. On
Horizontal Run
Wall
Firestop
Horizontal High
Wind Square
Termination
53'' Min.
Plus ¼''
Rise per
Foot
126718-01C