REMOTE CONTROL OPERATION Continued
LIGHT ADJUSTMENT
Transmits a light setting command to the control module to
adjust the light output level.
Available settings are 0 (off) – 6 with a factory default of 0 (off).
While in any mode of operation, press the LIGHT Zone to enter
Light Adjustment, then press the UP or DOWN buttons to raise
or lower the light output; press the MODE/SET Button or wait
for 15 seconds to accept the new setting.
LCD Displays:
When raising or lowering the light output level with the UP
or DOWN buttons, the light icon and light setting number
will flash in the LIGHT Zone.
CONTINUOUS PILOT OPERATION
To activate or deactivate the Continuous Pilot Feature, press
and hold the MODE/SET and UP Buttons simultaneously for 5
seconds.
LCD Display: When activated, CONT. PILOT will be displayed in
the MODE Zone.
CHILD-LOCK OPERATION
Child-Lock operation prevents any user input to the transmitter.
No mode of operation or feature may be adjusted when Child-
Lock is activated. All automatic functions will continue normally.
To activate or deactivate the Child-Lock feature, press and hold
the MODE/SET and DOWN Buttons simultaneously for 5 seconds.
LCD Displays:
When activated, the LOCK icon will appear in the MODE
Zone.
If any touch-zone or button is pressed when activated, the
LCD backlight will illuminate and the LOCK icon will flash
for 5 seconds in the MODE Zone.
SENSOR SAFETY OVERRIDE
Will only operate if the control is in MANUAL OFF mode.
Press and hold the FLAME Zone and the UP Button simultane-
ously activate the sensor safety override feature.
The module will ignore any sensor faults, continually emit an
igniter spark, and energize the PILOT operator output.
When the buttons are released, the control will immediately
return to MANUAL OFF mode.
LCD Display:
When the Sensor Safety Override feature is activated, CONT.
PILOT will flash on the LCD screen.
COMMUNICATION SAFETY
In manual ON and program modes of operation, the transmitter
will send a communication safety transmission every 15 - min-
utes. This signal is further processed by the ignition control
module to verify the transmitter is communicating properly.
32
DRL4543TEN
• Rating: 35,000/22,000 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Electronic
• Manifold Pressure: 3.5" w.c.
• Minimum Inlet Supply Pressure: 5" w.c.
• Maximum Inlet Supply Pressure: 10.5" w.c.
• Orifice: #33
DRL4543TEP
• Rating: 33,000/24,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Electronic
• Manifold Pressure: 10" w.c.
• Minimum Inlet Supply Pressure: 11" w.c.
• Maximum Inlet Supply Pressure: 13" w.c.
• Orifice: #50
Note: Use only original replacement parts. This will protect your
warranty coverage for parts replaced under warranty.
Contact authorized dealers of this product. If they can't supply
original replacement part(s), call IHP at 1-800-655-2008.
When calling, have ready:
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• purchase date
Usually, we will ask you to return the part to the factory.
You may have further questions about installation, operation, or
troubleshooting. If so, contact IHP at 1-800-655-2008. When
calling please have your model and serial numbers of your heater
ready.
You can also visit our web site at
IHP.US.com.
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply might be low (propane/LP units only)
You may feel your gas pressure is too low. If so, contact your local
gas supplier.
Superiorfireplaces.US.com

SPECIFICATIONS

REPLACEMENT PARTS

TECHNICAL SERVICE

SERVICE HINTS