Minimum Flow Adjustment For Hob Gas Taps - Baumatic BCD905SS Instruction Manual

90 cm single cavity dual fuel cooker
Table of Contents

Advertisement

Burner
Operating
pressure gas
mbar
G30 -
Butane
G31 -
Rapid
Propane
G20 -
Natural
G30 -
Butane
G31 -
Semi -
Propane
rapid
G20 -
Natural
G30 -
Butane
G31 -
Auxiliary
Propane
G20 -
Natural
G30 -
Butane
G31 -
Triple
Propane
Crown
G20 -
Natural
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
IMPORTANT: After changing the injectors YOU MUST follow the
minimum flow adjustment section below.

Minimum flow adjustment for hob gas taps.

All work must be carried out by a GASSAFE
registered engineer.
Rate
g/h
L/h
28 -
218
N/A
30
37
214
N/A
20
N/A
286
28 -
131
N/A
30
37
129
N/A
20
N/A
171
28 -
73
N/A
30
37
71
N/A
20
N/A
95
28 -
276
N/A
30
37
272
N/A
20
N/A
362
o Light the burner and set the knob at the minimum
position.
o Remove the knob from the tap. The adjustment
screw is located beside the valve body.
o Place a small bladed screwdriver in the centre of
the tap shaft.
o Unscrew the adjusting screw, in order to increase
the gas flow or tighten the adjusting screw to
decrease the gas flow.
35
Diameter
Heat Input
injector
(W)
1/100mm
Min
88
800
88
800
117 - Y
800
68
600
68
600
98 - Z
600
51
400
51
400
75 - X
400
98
1400
98
1400
135 - K
1400
By-Pass
Max
1/100mm
3000
3000
44
3000
1800
1800
34
1800
1000
1000
28
1000
3800
3800
62
3800