Minimum flow adjustment for hob gas taps.

All work must be carried out by a GASSAFE
registered engineer.
o Ignite the large (rapid) burner and set the control knob to the
minimum position.
o Remove the control knob to access a small adjusting screw.
o Using a suitable screwdriver, turn the screw clockwise to
decrease the flow of gas and make the flame smaller. Turn the
screw anti-clockwise to increase the flow of gas and make the
flame bigger.
o To establish the correct adjustment, the flame should be
approximately 3 – 4 mm in length. For Butane / Propane gas,
the adjusting screw must be tightly screwed in.
o Refit the control knob.
o Turn the control knob to maximum and then back to minimum
two or three times to make sure the flame does not go out when
the control knob is set to minimum.
o If the flame does go out then remove the control knob and
repeat the procedure again.
o Repeat these steps for the semi-rapid and auxiliary burners.
33