Minimum flow adjustment for hob gas taps.

All work must be carried out by a CORGI registered
engineer.
o Unscrew the adjusting screw, in order to increase the gas flow
or tighten the adjusting screw to decrease the gas flow.
o The correct adjustment is obtained when the flame has a
length of about 3 – 4 mm.
o For butane/propane gas, the adjusting screw must be tightly
screwed in.
o Refit the control knob.
o Make sure that the flame does not go out by quickly turning
from maximum flow to minimum flow. If it does then remove
the control knob and make further adjustments to the gas
flow, testing it again once the adjustment has been made.
o Switch the burner on and
set the knob at the
minimum position.
o Remove the knob from
the tap and place a small
bladed screwdriver to
the outside the tap.