Minimum flow adjustment for hob gas taps.

All work must be carried out by a CORGI registered
engineer.
o Light the burner and set the control knob at the minimum
position.
o Remove the knob from the tap and place a small bladed
screwdriver in the centre of the tap shaft.
o Unscrew the adjusting screw, in order to increase the gas flow
or tighten the adjusting screw to decrease the gas flow.
o The correct adjustment is obtained when the flame has a
length of about 3 – 4 mm.
o For butane/propane gas, the adjusting screw must be tightly
screwed in.
o Refit the control knob.
o Make sure that the flame does not go out by quickly turning
from maximum flow to minimum flow. If it does then remove
the control knob and make further adjustments to the gas
flow, testing it again once the adjustment has been made.
o IMPORTANT: If you are following this procedure after
converting the appliance to run on L.P.G.; YOU MUST
carry out a gas leak test and affix the category label
(supplied with the conversion kit) to the rear of the
appliance. This label will take the place of the one
already attached.