Global Parameters
Record search (ID=105)
Record search parameter is responsible for record searching order. Value of 0 arranging data
starting from newest, while value of 1 arranging data starting from oldest.
Minimum
Maximum
value
value
0
1
Link timeout (ID=107)
Link timeout in seconds, indicates link timeout after last record sending. Disconnection from
server is not immediate after data packet is sent. Module disconnect from server after indicated
timeout.
Minimum
Maximum
value
value
5
259200
8.2
Data acquisition and sending parameters
Time based acquire interval (ID=11)
Time interval in seconds, indicating condition to acquire new record. 0 – disabled.
Minimum
Maximum
value
value
0
9999999
Distance based acquire interval (ID=12)
Distance in meters, indicating condition to acquire new record. Record is stored when the
distance between previous record is greater than parameter‟s value. 0 – disabled
Minimum
Maximum
value
value
0
65535
Angle based coordinate acquisition (ID=13)
Angle in degrees, indicating condition to acquire new record. If angle difference between last
recorded coordinate and current position is greater than defined value, new record is stored. This
parameter is operational, when speed is higher then 10km/h. 0 – disabled
Recommended
Goes with (depends on) parameters
value
-
Data Send interval (ID=270)
Recommended
Goes with (depends on) parameters
value
-
Data Send interval (ID=270)
Recommended
Goes with (depends on) parameters
value
Distance based acquire interval
5
Angle based coordinate acquisition
Recommended
Goes with (depends on) parameters
value
Time based acquire interval (ID=11)
50
Angle based coordinate acquisition
(ID=12)
(ID=13)
(ID=13)
Value type
S8
Value type
U32
Value type
U32
Value type
U16