6.
FAULT TRACING LIST
6.1
G
ENERAL
This list will facilitate the rapid tracing of the most common types of
faults.
Before performing checks on the inverter you must disconnect all other
12V
or 24 V
DC
DC
6.2
T
ROUBLE SHOOTING
If the fault cannot be solved, consult your Victron Energy dealer.
Problem
The inverter does not
work when switched
on:
The LED 'low batt.'
flashes:
The LED 'low batt.'
illuminates:
The LED 'overload'
flashes:
The LED 'overload'
illuminates:
manual
equipment from the batteries.
Possible cause
The input voltage is too
high or too low.
The plus '+' and the
minus '-' of the
batteries and the
inverter do not
correspond.
The battery voltage is
low.
The inverter is
switched off because
the battery voltage was
too low.
The load connected to
the inverter is higher
than the nominal load.
The inverter is
switched off due to a
too high load.
Solution
Make sure that the
input voltage is within
the correct values, see
section 7 for these
values.
Switch the inverter off
and connect the
battery correctly.
Recharge the batteries
or check the battery
connections.
Recharge the batteries
or check the battery
connections.
Disconnect a part of
the load.
Disconnect a part of
the load.
25