Advertisement

Quick Links

Inversores Phoenix
1200VA - 5000VA (por módulo)
Phoenix Inverter
24/5000
Phoenix Inverter Compact
24/1600
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: sales@victronenergy.com | www.victronenergy.com
SinusMax – Diseño superior
Desarrollado para uso profesional, la gama de inversores Phoenix es ideal para innumerables aplicaciones. El
criterio utilizado en su diseño fue el de producir un verdadero inversor sinusoidal con una eficiencia optimizada
pero sin comprometer su rendimiento. Al utilizar tecnología híbrida de alta frecuencia, obtenemos como
resultado un producto de la máxima calidad, de dimensiones compactas, ligero y capaz de suministrar potencia,
sin problemas, a cualquier carga.
Potencia de arranque adicional
Una de las características singulares de la tecnología SinusMax consiste en su muy alta potencia de arranque. La
tecnología de alta frecuencia convencional no ofrece un rendimiento tan extraordinario. Los inversores Phoenix,
sin embargo, están bien dotados para alimentar cargas difíciles, como frigoríficos, compresores, motores
eléctricos y aparatos similares.
Potencia prácticamente ilimitada gracias al funcionamiento en paralelo y trifásico.
Hasta 6 unidades del inversor pueden funcionar en paralelo para alcanzar una mayor potencia de salida. Seis
unidades 24/5000, por ejemplo, proporcionarán 24 kW / 30 kVA de potencia de salida. También es posible su
configuración para funcionamiento trifásico.
Transferencia de la carga a otra fuente CA: el conmutador de transferencia automático
Si se requiere un conmutador de transferencia automático, recomendamos usar el inversor/cargador MultiPlus
en vez de este. El conmutador está incluido es este producto y la función de cargador del MultiPlus puede
deshabilitarse. Los ordenadores y demás equipos electrónicos continuarán funcionando sin interrupción, ya que
el MultiPlus dispone de un tiempo de conmutación muy corto (menos de 20 milisegundos).
Interfaz para el ordenador
Todos los modelos disponen de un Puerto RS-485. Todo lo que necesita conectar a su PC es nuestro interfaz
MK2 (ver el apartado "Accesorios"). Este interfaz se encarga del aislamiento galvánico entre el inversor y el
ordenador, y convierte la toma RS-485 en RS-232. También hay disponible un cable de conversión RS-232 en
USB. Junto con nuestro software VEConfigure, que puede descargarse gratuitamente desde nuestro sitio Web
www.victronenergy.com, se pueden personalizar todos los parámetros de los inversores. Esto incluye la tensión
y la frecuencia de salida, los ajustes de sobretensión o subtensión y la programación del relé. Este relé puede,
por ejemplo, utilizarse para señalar varias condiciones de alarma distintas, o para arrancar un generador.
Los inversores también pueden conectarse a VENet, la nueva red de control de potencia de Victron Energy, o a
otros sistemas de seguimiento y control informáticos.
Nuevas aplicaciones para inversores de alta potencia
Las posibilidades que ofrecen los inversores de alta potencia conectados en paralelo son realmente asombrosas.
Para obtener ideas, ejemplos y cálculos de capacidad de baterías, le rogamos consulte nuestro libro
on board"
(electricidad a bordo), disponible gratuitamente en Victron Energy y descargable desde
www.victronenergy.com.
www.victronenergy.com
"Electricity

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C12/1200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Victron energy C12/1200

  • Page 1 Los inversores también pueden conectarse a VENet, la nueva red de control de potencia de Victron Energy, o a otros sistemas de seguimiento y control informáticos.
  • Page 2 Hay varios modelos disponibles (ver la documentación del monitor de baterías). Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40 E-mail: sales@victronenergy.com | www.victronenergy.com...
  • Page 3 E (T-sense) F (TR-charge) G (V-sense) Quick Installation Guide www.victronenergy.com Compact Phoenix Inverter 12V 24V 1200VA 1600VA 230Vac ( V-sense) Included Not included E (T-sense) N T R I C O U LT A L M D IG IT Included Not included N GND AC-OUT...
  • Page 4 Manual Handleiding Manuale Anleitung Manual Phoenix Inverter Compact 12 | 1200 230V 24 | 1200 230V 12 | 1600 230V 24 | 1600 230V...
  • Page 6 DESCRIBED HERE IN. Victron Energy B.V. reserves the right to revise and improve its products as it sees fit. This publication describes the state of this product at the time of its publication and may not reflect the product at all...
  • Page 8: Safety Instructions

    1. SAFETY INSTRUCTIONS General Please familiarize yourself with the safety features and instructions by first reading the documentation supplied with this product before using the equipment. This product has been designed and tested in accordance with international standards. The equipment must be used exclusively for the purpose for which it was designed.
  • Page 9: Transport And Storage

    Transport and Storage Ensure that the mains power and battery leads have been disconnected before storing or transporting the product. No liability can be accepted for any transport damage if the equipment is shipped in non- original packaging. Store the product in a dry environment; the storage temperature must be between -20° C and 60°...
  • Page 10 2. DESCRIPTION 2.1 General SinusMax - Superior engineering Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications. The design criteria have been to produce a true sine wave inverter with optimised efficiency but without compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact dimensions, light in weight and capable of supplying power, problem-free, to any load.
  • Page 11: Operation

    3. OPERATION 3.1 On/Off Switch When switched to "on", the product is fully functional. The inverter will come into operation and the LED "inverter on" will light up. 3.2 Remote control Remote control is possible with a simple on/off switch or with a Phoenix Inverter Control panel.
  • Page 12: Installation

    4. INSTALLATION This product should be installed by a qualified electrician. 4.1 Location The product must be installed in a dry and well-ventilated area, as close as possible to the batteries. There should be a clear space of at least 10cm around the appliance for cooling.
  • Page 13: Connection Of Battery Cables

    4.2 Connection of Battery cables In order to fully utilize the full capacity of the product, batteries with sufficient capacity and battery cables with sufficient cross section should be used. See table. 24/1200 24/1600 12/1200 12/1600 Recommended cross section (mm 10 m 1) preassembled cable length: 1.5 m 24/1200...
  • Page 14: Optional Connections

    4.3 Connection of the AC cabling This is a Safety Class I product (supplied with a protective grounding terminal). The neutral wire of the AC output of this inverter is connected to the chassis. This is to ensure proper functioning of a GFCI (or RCCB) to be installed in the AC output of the Inverter.
  • Page 15 4.4.3 Parallel Connection The inverters can be connected in parallel with several identical devices. To this end, a connection is established between the devices by means of standard RJ45 UTP cables. The system (one or more inverters plus optional control panel) will require subsequent configuration (see Section 5).
  • Page 16 5. CONFIGURATION Settings may only be changed by a qualified engineer. Carefully read the instructions before changes are made. Batteries should be placed in a dry and well-ventilated area during charging. 5.1 Standard settings: ready for use On delivery, the Phoenix inverter is set to standard factory values. In general, these settings are suitable for stand-alone operation.
  • Page 17 Search Mode (Applicable in stand-alone configuration only) If search mode is ‘on’, the power consumption in no-load operation is decreased by approx. 70%. In this mode the Compact, when operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period.
  • Page 18: Configuration By Computer

    If the computer has no RS232 connection, but does have USB, a RS232-to-USB interface cable is needed. Both are available from Victron Energy. 5.3.2 VE.Bus System Configurator and dongle For configuring advanced applications and/or systems with four or more inverters, VE.Bus System Configurator software must be used.
  • Page 19 5.5 Configuration with DIP switches Some settings can be changed with DIP switches Procedure: a) Turn the Compact on, preferably without load. b) Set the dipswitches as required. c) Store the settings by moving Dip switch 8 to “on” and back to “off”. 5.5.1.
  • Page 20: Maintenance

    Avoid moisture and oil/soot/vapours, and keep the device clean. 7. TROUBLE SHOOTING TABLE Proceed as follows for quick detection of common faults. Consult your Victron Energy dealer if the fault cannot be resolved. Problem Cause Solution...

Table of Contents