Earth connection
Illustration 2.
3.4
C
ONNECTING THE BATTERY CABLES
To take full advantage of the Phoenix inverter, particularly under
peak/surge load conditions, the inverter should be connected to the battery
with special battery cables. See section 3.2.2.
Connection procedure battery cables
The following procedure is to be carried out carefully.
step 1.
Unscrew the four screws of the front panel.
step 2.
Connect the battery cables: the '+' (red) to the left and the '-'
(black) to the right.
step 3.
If the DC-input cables to the inverter are connected in
reverse polarity (+ on - and – on +), the inverter will not work.
step 4.
If the inverter does not work disconnect the cables and re-connect them
correctly.
manual
The ground connection (earth protection
conductor) from the mains is located on the
AC-terminal block (Illustration 1). The circuit
is functional only if the cabinet is connected
to earth. A M4 earth screw is fitted in the
bottom of the cabinet. Connect the cabinet
earth terminal to earth (Illustration 2).
The earth for vessels is the hull or earth plate;
for motor vehicles it is the chassis.