Englisch, Dutch, French or German language, contact Victron Energy B.V. Victron Energy B.V. reserves the right to revise and improve its products as it sees fit. This publication describes the state of this product at the time of its publication and may not reflect the product at all times in the future.
230 or 115 Volt power supply is indispensable. Victron Energy has the ideal power source for all kinds of electrical appliances used for household, technical and industrial purposes, including instruments susceptible to interference. All of these applications require a high quality power supply in order to function properly.
Do not obstruct the airflow around the inverter. Leave at least 10 centimetres clearance around the inverter. When the inverter is running too hot, it will shut down. When the inverter has reached a safe temperature level the unit will automatically restart again. victron energy manual...
THE Ph 24/300 AND Ph 24/650 MUST BE CONNECTED ONLY TO A 24V BATTERY. The inverter will not operate from a 12V battery. The inverter will be damaged when the battery voltage is higher than 31V. victron energy victron energy victron energy victron energy manual...
Reverse polarity connection of the battery CAUTION wires can damage the inverter! Damage caused by reversed polarity is not covered by the warranty. Make sure the power switch is in the OFF ‘0’ position before connecting the battery. victron energy manual...
Page 8
AC outlet and to the negative wire of the DC input. The Ph 12/500 and Ph 24/650 models have an earthed case which is not directly connected to any DC input wire victron energy victron energy victron energy victron energy manual...
START CURRENT, IT CAN CAUSE WARNING YOUR COMPUTER TO REBOOT DUE TO A SUDDEN VOLTAGE DROP. NEVER CONNECT THE INVERTER’S OUTPUT TO THE AC DISTRIBUTION GRID, SUCH AS YOUR HOUSEHOLD AC WALL OUTLET. IT WILL DAMAGE THE INVERTER. CAUTION victron energy manual...
DC VOLTAGE WHEN THE BATTERIES ARE DISCONNECTED. To avoid sparks or short inverter operation, it is advisable to switch on the inverter for 10 WARNING seconds after battery disconnection, before you transport the inverter. victron energy victron energy victron energy victron energy manual...
In this case you have to connect an additional load to the AC output. The adjusted load sense level can slightly change with DC input voltage and temperature. victron energy manual...
Inverter temperature too high. Cooling down ( Three flashes per second ) Reserved ( Four flashes per second ) Ph12/225, Ph24/300 models: ON, inverter in normal operation Ph12/500, Ph24/650 models: Overload, output in ‘current limit’ victron energy victron energy victron energy victron energy manual...
Blown inverter fuse. Replace damaged fuse with the correct type. Make sure you disconnect the battery before changing the fuse. The Ph 12/500 and Ph 24/650 has to be returned for service. Very poor battery condition. Replace battery. victron energy manual...
Page 14
Check if the AC power cord between the inverter and the connected equipment is OK. Any physical damage on the power cord can produce a short circuit. Be careful in these situations!. victron energy victron energy victron energy victron energy manual...
Page 15
Move the inverter to a cooler place or provide additional cooling by an external fan. Note: Don’t turn-off the inverter when it’s operating in an ‘Inverter temperature too high. Cooling down’ error. The inverter needs this error time to cool down. victron energy manual...
Page 16
If none of the above remedies helps to solve the problem you encounter, contact your local Victron Energy distributor for further help and/or possible repair of your inverter. Do not open the inverter yourself, there are dangerous high voltages present inside. Opening the inverter will directly void your 12 months warranty period.
The inverter complies with the EN50081-1 Generic Emissions Standard following standards : EN50082-1 Generic Immunity Standard EN60950 Safety Standard EN60742 Transformer Standard Note : the given specifications are subject to change without notice victron energy victron energy victron energy victron energy manual...
Page 19
Measured with resistive load. Undervoltage limit is dynamic. This limit decreases with increasing load to compensate the voltage drop across cables and connections. Measured with nominal load at Ta=25ºC and at nominal input and outputvoltage. victron energy manual...
(for example 24 V ). The result is the total battery capacity-consumption in Ah's. Multiply this value with a safety factor of 1,7 and the result is the recommended minimum battery capacity. victron energy victron energy victron energy victron energy manual...