Object
Port
• Port Description
Link
Current Link Speed
Configured Link Speed
Flow Control
• Maximum Frame Size
• Excessive Collision
Mode
• Power Control
Description
This is the logical port number for this row,
Managed Switch.
This function provides input per port description and the available letters is 12.
The current link state is displayed graphically. Green indicates the link is up and
red that it is down.
Provides the current link speed of the port.
Select any available link speed for the given switch port. Draw the menu bar to
select the mode.
All- Setups whole ports with the same setting.
Disable – Shutdowns the port manually.
10 HDX - Forces setting 10Mbps/Half-Duplex mode.
10 FDX - Forces setting 10Mbps/Full-Duplex mode.
100 HDX - Forces setting 100Mbps/Half-Duplex mode.
100 FDX - Forces setting 100Mbps/Full-Duplex mode.
1G FDX - Force setting 1000Mbps/Full-Duplex mode.
10G FDX – Forces setting 10000Mbps/Full-duplex mode.
Auto Fiber (10G) – Setup 10G firber port for negotiation automatically.
Auto Fiber - Setup 1G fiber port for negotiation automatically.
Auto - Setup Auto negotiation.
When Auto Speed is selected on a port, this section indicates the flow control
capability that is advertised to the link partner.
When a fixed-speed setting is selected, that is what is used. The Current Rx
column indicates whether pause frames on the port are obeyed, and the Current
Tx column indicates whether pause frames on the port are transmitted. The Rx
and Tx settings are determined by the result of the last Auto-Negotiation.
Check the configured column to use flow control. This setting is related to the
setting for Configured Link Speed.
Enter the maximum frame size allowed for the switch port, including FCS. The
allowed range is 1518 bytes to 9600 bytes for TP port and 9000 bytes for Fiber
port.
Configure port transmit collision behavior.
Discard: Discard frame after 16 collisions (default).
Restart: Restart back off algorithm after 16 collisions.
The Usage column shows the current percentage of the power consumption per
port. The Configured column allows for changing the power savings mode
parameters per port.