The page includes the following fields:
Object
Port Members
Key Parameters
• Any
• Ethernet
• LLC
• SNAP
• IPv4
Description
Check the checkbox button in case you what to make any port member of the
QCL entry. By default all ports will be checked
Key configuration is described as below:
Tag Value of Tag field can be 'Any', 'Untag' or 'Tag'.
VID Valid value of VLAN ID can be any value in the range 1-4095 or
'Any'; user can enter either a specific value or a range of VIDs.
PCP Priority Code Point: Valid value PCP are specific(0, 1, 2, 3, 4, 5,
6, 7) or range(0-1, 2-3, 4-5, 6-7, 0-3, 4-7) or 'Any'.
DEI Drop Eligible Indicator: Valid value of DEI can be any of values
between 0, 1 or 'Any'.
SMAC Source MAC address: 24 MS bits (OUI) or 'Any'.
DMAC Type Destination MAC type: possible values are unicast(UC),
multicast(MC), broadcast(BC) or 'Any'.
Frame Type Frame Type can have any of the following values:
1.
Any
2.
Ethernet
3.
LLC
4.
SNAP
5.
IPv4
6.
IPv6
Note: All frame types are explained below.
Allow all types of frames.
Ethernet Type Valid ethernet type can have value within 0x600-0xFFFF or 'Any'
but excluding 0x800(IPv4) and 0x86DD(IPv6), default value is 'Any'.
SSAP Address Valid SSAP(Source Service Access Point) can vary from
0x00 to 0xFF or 'Any', the default value is 'Any'
DSAP Address Valid DSAP(Destination Service Access Point) can vary
from 0x00 to 0xFF or 'Any', the default value is 'Any'
Control Address Valid Control Address can vary from 0x00 to 0xFF or 'Any',
the default value is 'Any'
PID Valid PID(a.k.a ethernet type) can have value within 0x00-0xFFFF or 'Any',
default value is 'Any'
Protocol IP protocol number: (0-255, TCP or UDP) or 'Any'
Source IP Specific Source IP address in value/mask format or 'Any'. IP and
Mask are in the format x.y.z.w where x, y, z, and w are decimal numbers
between 0 and 255. When Mask is converted to a 32-bit binary string and
read from left to right, all bits following the first zero must also be zero
224