WEEKLY MAINTENANCE

(Every 10 Hours of Use)
1. Flip the ReadySpace rollers end-for-end every 10
hours of use (Figure 32). The roller life is rated for
at least 100 hours of use under normal cleaning
conditions. If the gap between the two rollers is
greater than 4mm replace the rollers.
FIG. 32
2. Remove any debris build--up from the underside of
the scrub head (Figure 33).
FIG. 33
3. Remove the front and rear roller vacuum shoe
covers and remove any debris (Figure 34).
FIG. 34
4. Remove any entangled carpet fibers and debris
from the brushes (Figure 35). Replace brushes if
worn. To determine when to replace worn brushes
observe the brush pressure meter.
Tennant 1610 (10- -05)
Home
Find... Go To..
If unable to adjust the pressure into the green
zone this may be a good indication that the
brushes should be replaced.
FIG. 35
5. Remove any debris lodged in the carpet extraction
vacuum shoe (Figure 36).
FIG. 36
6. Inspect the spray tips for proper spray pattern
(Figure 37). If spray pattern is obstructed, clean or
replace the spray tips (See MONTHLY
MAINTENANCE).
ReadySpace
Spray Tips (2)
Restorative Extraction
Spray Tips (2)
FIG. 37