PREPARING MACHINE FOR RESTORATIVE EXTRACTION CLEANING

FOR SAFETY: Before preparing machine,
turn machine off and remove key.
Step 1:
Unlatch the idler plates and remove
the two ReadySpace rollers if installed.
IDLER
PLATE
Step 2:
Disconnect the
vacuum hose and
the vacuum tube
from the rear
ReadySpace
vacuum shoe if
installed.
READYSPACE
VACUUM SHOE
(2) 6mm SOCKET
HEAD CAP SCREWS
Step 3:
Disconnect the solution flush lines from the
rear vacuum shoe (See DETAIL A).
Step 4:
Remove the ReadySpace vacuum shoe.
6 mm hex head tool required.
Step 5:
Install the two extractor
brushes (See DETAIL B).
IDLER
PLATE
(2) 6mm SOCKET
HEAD CAP
SCREWS
Step 6:
Install the extractor vacuum shoe.
Make sure that the shoe is positioned behind the
two support tabs. Use the screws removed from
Step 4. Connect the vacuum hose to the extractor
vacuum shoe as shown.
Tennant 1610 (10- -05)
Equipment Needed:
1) Two Extractor Brushes
2) Extractor Vacuum Shoe
3) Vacuum Shoe Head Tool
(supplied with machine)
VACUUM TUBE
EXTRACTOR
VACUUM
SHOE
Home
Find... Go To..
SCRUB HEAD
SOLUTION
FLUSH LINE
NOTE: To prevent misplacing,
DO NOT remove the disabled
solution flush lines and the
vacuum tube from the scrub head.
TOP VIEW
The brushes V--pat-
tern (chevron) should
point towards each
other.
SUPPORT TABS (2)
OPERATION
3
2
DETAIL A
Push the retainer tab
upward to disengage the
solution flush line tip.
DETAIL B