Installation Planning; Appliance Height In Framing; Appliance Depth In Framing - Valor 1100IN Installation & Owner's Manual

Table of Contents

Advertisement

Installer——READ THIS FIRST
Only quali ed licensed or trained personnel
should install this appliance.
1. YOU NEED TO KNOW FROM THE
HOMEOWNER:
- The height of the unit and hearth if used;
- The thickness and type of the wall  nish
around the  rebox opening;
- What accessories (trim, decorative lighting,
etc.) will be installed with this  replace;
- The venting con guration.
2. Unpack the appliance, removing all items packed
inside and around the appliance.
3. Check that you have everything, using the Pack
Content sheet. Also, check that you have:
a fuel bed (logs or glass) (packed separately)
a set of liners (packed separately)
4. Finish the framing.
5. Fit the appliance into framing and fi x it to the
framing.
6. Remove the window of the appliance.
7. Install the venting system and tape vent pipe joints.
8. Position the restrictor.
9. Connect the electrical wiring for optional electric
accessories if used.
10. Install the optional electric accessories if used.
11. Connect and test the gas supply.
12. Install the liners.
13. Install the fuel bed.
14. Refi t the window and the hot glass safety plate
if removed.
15. Initialize the remote control system.
16. Verify the operation and adjust aeration settings.
17. Install the remote control handset wall holder.
18. Instruct the homeowner on the operation and
maintenance of the  replace.
19. Finish the wall around the fi replace.
20. Install the surround trim and barrier screen.

Installation Planning

Appliance Height in Framing

Hearth considerations
• Only a non-combustible hearth can be installed in
front of the appliance if within 4" of the bottom of the
appliance.
• The top surface of the non-combustible hearth must
be at the same level as appliance bottom panel
when using certain trims and accessoires—see
page 48.
• The non-combustible hearth in front of the
appliance, if within 4" of the bottom of the appliance,
must include the 1/2" Micore insulation board
provided to be used as thermal break between non-
combustible and combustible material underneath.

Appliance Depth in Framing

• 1130 Minimal Trim installs at framing stage and
the appliance position is fi xed in the framing. Wall
fi nishes butt up to the frame of the 1130 Minimal
Trim.
• All other trims install after the wall fi nish is applied.
The perimeter of the trims overlap the wall fi nish;
therefore the thickness of any wall fi nish materials
must be taken into consideration. The trims have
enough adjustability to allow up to 3/4" thick material
applied over top of the 1/2" thick non-combustible
board. Otherwise the appliance position within the
framing must be adjusted to allow the additional
thickness—see pages 47-48.
QUALIFIED
INSTALLER
39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1100ip1150ilp1150iln1100in ng1100ip lpg