Use the same method of programming as section [12].
ZONE
LIGHT
[1]
ON = Able to answer call from downloading
computer
• OFF = Cannot answer call from downloading
computer
[2]
ON = Enable callback to downloading computer
• OFF = Disable callback to downloading computer
[3]
ON = Enable answering machine over-ride
• OFF = Disable answering machine over-ride
[4]
ON = Show bypass status while armed or disarmed
• OFF = Show bypass status while disarmed only
[5]
ON = Set for AC = 50 Hz
• OFF = Set for AC = 60 Hz
[6]
ON = Restore on bell time-out (if zone is restored)
• OFF = Restore as follower (when zone restores)
• Factory default
Downloading and Answering Machines
If zone light [3] is ON and the panel is called for 1 or 2 rings only and
then called back within a variable time from 1 to 249 seconds (this
time set in section [33]), the panel will then answer the second call
on the first ring.
If zone light [3] is OFF, it is assumed that there is no answering
machine connected to the telephone line, and the panel will capture
the line after the set number of rings.
If zone light [3] is OFF and an answering machine is connected and
is set to answer before the panel, the panel will be unable to receive
a call from the downloading computer. If the panel is set to answer
before the answering machine, the answering machine will be
unable to receive incoming calls.
[32]
5th System Option Code
Use the same method of programming as section [12].
ZONE
LIGHT
[1]
ON = Loss of AC will not cause an AC trouble
• OFF = Loss of AC will cause AC trouble
[2]
ON = No bell during Auto-Arm (burst every 10
seconds is silenced)
• OFF = 1 burst of bell / siren every 10 seconds
during Auto-Arm pre-alert
[3]
• ON = Home-Away zones will have an entry
delay when tripped
OFF = Home-Away zones act as interior when tripped
[4]
ON = Quick-Exit is enabled ([
1 transition of a delay zone)
• OFF = Quick-Exit is disabled
[5]
ON = Auxiliary delay loops can be force armed
• OFF = Auxiliary delay loops cannot be force armed
[6]
• ON = All zones except fire will be shunted for
60 seconds upon power-up
OFF = All zones are active upon power-up
• Factory default
[33]

Answering Machine Double Call Timer

This location sets the amount of time between calls when using the
answering machine over-ride feature. See section [31], light 3.
[34]
6th System Option Code
Use the same programming method as in Section [12].
ZONE
LIGHT
[1]
ON = Audible Exit Delay with urgency
• OFF = Standard Exit Delay
14
*
][0] ignores
[2]
ON = Bell Squawk during Exit Delay
• OFF = No Bell Squawk during Exit Delay
[3]
ON = Audible Exit Fault enabled
• OFF = Audible Exit Fault disabled
[4]
ON = Urgency applied to Entry Delay
• OFF = Standard Entry Delay
[5]
ON = Bell Squawk during Entry Delay
• OFF = No Bell Squawk during Entry Delay
[6]
ON = [F] Key disabled
• OFF = [F] Key enabled
• Factory default
When Light 3 is ON (Audible Exit Fault):
is armed and a Standard Delay Zone is left open at the end of the
Exit Delay, the bell/siren will sound a steady tone for the duration
of the Entry Delay.
Entry and Exit Delay Urgency:
selected for the audible Entry Delay, the keypad will sound a
constant tone during the Entry Delay. During the last 10 seconds
of the Entry Delay, the keypad will sound a pulsing tone to warn
that the delay is about to expire.
When the urgency option is selected for the audibile Exit Delay, the
keypad will sound a pulsing tone during the Exit Delay. During the
last 10 seconds of the Exit Delay, the keypad will sound a faster
pulsing tone to warn that the delay is about to expire.
[35]

LINKS1000 Test Reporting Code

Cellular communications through the LINKS1000 Cellular Alarm
Transmitter will be tested periodically according to the test
transmission times programmed in Sections [17] and [19]. The
reporting codes programmed in Section [35] will be transmitted
during the cellular transmission test.
When the cellular test transmission is completed, the Automatic
Test Code programmed in Section [10] will be transmitted over the
regular telephone line.
[36]

Keypad Lockout Control

Program two 2-digit numbers in this section.
The first entry determines how many invalid codes may be entered
before the keypad is locked out and will not accept any further
entries. Program a number from 00 to 99; 00 disables the keypad
lockout function.
The second entry determines how long, in minutes, the keypad
will be locked out once the programmed number of invlaid codes
are entered. Program a time from 00 to 99 minutes.
[90]

Installer's Lockout Enable

This feature is enabled by entering [90] while in the installer's
programming mode. A factory default (hardware or software) will
not reset the installer's code or the download access code once this
feature is enabled. A panel that has this feature enabled will give a
distinct audible indication upon power-up. This indication is the
phone line relay clicking 10 times. Make sure that your new
installer's code has been entered correctly before enabling this
feature because there is no way of re-entering the programming
mode without the new installer's code. Remember that even a reset
to the factory default will not change the installer's code back to the
default.
NOTE: Panels returned to DSC with the installer's lockout feature
enabled and no other apparent problems will be subject to an
additional service charge.
[91]

Installer's Lockout Disable

Entering [91] when in the installer's programming mode will disable
the installer's lockout feature.
When the system
When the urgency option is

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents