Storage System Addition; Addition Without Server Rebooting; Addition With Server Rebooting - Fujitsu ETERNUS Multipath Driver V2 User Manual

Table of Contents

Advertisement

Chapter 5 Changing the Multipath Configuration (SAS Connection for RHEL-AS4, RHEL-ES4, RHEL5, or SLES10)

5.1 Storage System Addition

5.1
Storage System Addition
5.1.1

Addition without Server Rebooting

Extra storage systems can be added without shutting down the server. Use the following procedure.
Procedure
1
Attach the hardware.
Set up the storage system so that its LUs are accessible to the server, and then connect it to the server.
For details on the settings, refer to the storage system manual.
2
Use the "iompadm info" command to check the result.
When the new storage system is connected to the server, it should be automatically recognized and
incorporated in the list.
[Example]
# /opt/FJSVmpd/bin/iompadm info
3
Set its Max Throttle value.
Execute the "mpdconfig -m" command to set a Max Throttle value for the new storage system. Refer to
the software information (/opt/FJSVmpd/manual/english/readme.pdf) for the Max Throttle value
computation method.
[Example]
# /opt/FJSVmpd/bin/mpdconfig -m
4
If by-id names are not being used, or are being used with FUJITSU Software PRIMECLUSTER
Global Disk Services installed, use the "mpdconfig -s" command to set the recognition order.
[Example]
# /opt/FJSVmpd/bin/mpdconfig -s
5.1.2

Addition with Server Rebooting

Same as for FC/FCoE connection.
Refer to
"4.1.2 Addition with Server Rebooting" (page
FUJITSU Storage ETERNUS Multipath Driver V2 User's Guide for Linux
Copyright 2014 FUJITSU LIMITED
56).
66
End of procedure
P2U3-0031-15ENZ0