FLOOR PROTECTION REQUIREMENTS
A
EXTENDING DISTANCE, BACK
B
EXTENDING DISTANCE, RIGHT SIDE
C
EXTENDING DISTANCE, LEFT SIDE
D
EXTENDING DISTANCE, FRONT
FLOOR PROTECTOR MUST BE NON-COMBUSTIBLE MATERIAL. IT MUST EXTEND BENEATH HEATER, AND
TO THE FRONT / SIDES / REAR AS INDICATED.
FOR REAR-VENT THE FLOOR PROTECTOR MUST BE UNDER CHIMNEY CONNECTOR AND AT LEAST 2'' BEY-
OND ON EACH SIDE
FLOOR PROTECTECTOR MUST BE LISTED TO UL 1618- TYPE 1
Distance to furniture
The recommended minimum distance from stove to furniture is 30 inches. Note that some
furniture is more easily affected by heat and may need to be moved to a greater distance. This
is your responsibility.
In addition other combustible materials, away from the stove. In general, a distance of 30 inches
must be maintained between the stove and moveable combustible item such as drying clothes,
newspapers, firewood etc.
WARNING:
NEVER DRAW COMBUSTION AIR FROM A WALL, FLOOR OR CEILING CAVITY OR FROM ANY
ENCLOSED SPACE SUCH AS AN ATTIC OR GARAGE.
DO NOT INSTALL IN SLEEPING ROOM.
CAUTION: DO NOT INSTALL IN A MOBIL HOME
NON -COMBUSTIBLE MATERIAL BENEATH STOVE
USA
-
6''
6''
16''
CANADA
8'' (200 mm.)
8'' (200 mm.)
8'' (200 mm.)
18'' (450 mm.)