Solectria Renewables PVI 2500 Installation And Operation Manual page 32

Solectria residential/commercial grid-tied photovoltaic inverter
Hide thumbs Also See for PVI 2500:
Table of Contents

Advertisement

PVI 1800/PVI 2500(Rev A)
Overview error codes
Code
Designation
Hardware error, internal
101
communication interrupted
203
Grid frequency too high
204
Grid frequency too low
205
Extreme grid over-voltage
206
Grid over-voltage
207
Grid under-voltage
208
Extreme grid under-voltage
Internal fault on the device
301
or
blown GFDI fuse
302
Excessively high temperature
506
Ground fault current > than 0.8 A The inverter switches off
Condition
The inverter resumes feeding the grid
when automatic switching on of the
inverter reconnects it with the grid
The inverter switches to normal
power/feed mode as soon as the grid
frequency returns to its nominal value
The inverter switches to normal
power/feed mode as soon as the grid
frequency returns to its nominal value
The inverter switches to normal
power/feed mode as soon as the grid
voltage returns to its nominal value
The inverter switches to normal
power/feed mode as soon as the grid
voltage returns to its nominal value
The inverter switches to normal
power/feed mode as soon as the grid
voltage returns to its nominal value
The inverter switches to normal
power/feed mode as soon as the grid
voltage returns to its nominal value
The inverter switches off
The inverter switches off and switches
back into power feed mode when the
temperature has dropped to the normal
operating temperature
32
Installation and Operation Manual
Solution
The service technician should be
informed if this error code has been
seen repeatedly or continuously
Check grid frequency
The service technician should be
informed if this problem occurs on a
regular basis
Check grid frequency
The service technician should be
informed if this problem occurs on a
regular basis
Check grid voltage
The service technician should be
informed if this problem occurs on a
regular basis
Check grid voltage
The service technician should be
informed if this problem occurs on a
regular basis
Check grid voltage
The service technician should be
informed if this problem occurs on a
regular basis
Check grid voltage
The service technician should be
informed if this problem occurs on a
regular basis
Check the GFDI fuse
Please contact your installer/service
technician or Solectria Renewables. We
recommend switching off the inverter to
prevent any damage occurring to it.
Note:
this condition can occur during
operation in weak sunlight. See page 31
Check to ensure that the inverter is not
subject to direct sunlight. Please
observe the description of mounting.
Please contact your installer/service
technician or Solectria Renewables if
this measure does not eliminate the fault
Check installation
DOCR-070570-A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pvi 1800

Table of Contents