6-2-3.
DUCT TYPE
This table is created using the maximum capacity.
MODEL
: ARG22LM x 2
AFR
36.7
°CDB
-15
-10
-5
0
5
7
10
15
20
24
MODEL
: ARG24LM x 2
AFR
36.7
°CDB
-15
-10
-5
0
5
7
10
15
20
24
AFR: Air Flow Rate (m³/min.)
TC: Total Capacity (kW)
IP: Input Power (kW)
°CDB
16
°CWB
TC
IP
-16
10.91
4.71
-11
12.16
4.96
-7
13.54
5.15
-2
15.13
5.16
3
16.44
5.16
6
17.01
5.15
8
17.29
5.16
10
17.83
5.08
15
18.52
4.96
18
19.15
4.87
°CDB
16
°CWB
TC
IP
-16
11.60
5.43
11.32
-11
13.36
5.70
13.04
-7
14.86
5.91
14.51
-2
16.43
5.91
16.04
3
18.18
5.91
17.75
6
18.90
5.91
18.45
8
19.30
5.91
18.84
10
19.77
5.83
19.30
15
20.59
5.70
20.10
18
21.11
5.62
20.61
- (03-42) -
Indoor temperature
18
20
TC
IP
TC
IP
10.65
4.81
10.39
4.91
11.87
5.06
11.58
5.17
13.22
5.26
12.90
5.37
14.77
5.27
14.41
5.37
16.05
5.26
15.66
5.37
16.61
5.26
16.20
5.37
16.88
5.26
16.47
5.37
17.41
5.18
16.98
5.29
18.08
5.06
17.64
5.16
18.69
4.97
18.24
5.07
Indoor temperature
18
20
TC
IP
TC
IP
5.54
11.05
5.65
5.82
12.72
5.94
6.04
14.15
6.16
6.03
15.65
6.16
6.04
17.31
6.16
6.04
18.00
6.16
6.04
18.38
6.16
5.95
18.82
6.07
5.82
19.61
5.94
5.74
20.10
5.86
22
24
TC
IP
TC
IP
10.13
5.01
9.87
5.11
11.29
5.27
11.00
5.37
12.58
5.48
12.25
5.58
14.04
5.48
13.68
5.59
15.27
5.48
14.88
5.59
15.80
5.48
15.39
5.58
16.05
5.48
15.64
5.59
16.56
5.40
16.13
5.48
17.20
5.27
16.76
5.34
17.78
5.17
17.33
5.25
22
24
TC
IP
TC
IP
10.77
5.76
10.49
5.88
12.40
6.06
12.08
6.18
13.80
6.28
13.44
6.41
15.26
6.28
14.86
6.40
16.88
6.28
16.45
6.41
17.55
6.28
17.10
6.41
17.92
6.28
17.46
6.41
18.35
6.19
17.88
6.28
19.12
6.05
18.63
6.14
19.60
5.98
19.10
6.07