Double auto swing
z
Combination of up/down and right/left air direction swing allows three-dimensional air direction
control.
Since up/down air direction flaps operate automatically, according to the operating mode of the
unit, it is possible to set the air direction based on the operating mode.
Right and Left Swing
1
2
5 steps selectable
Fresh-air intake
z
INDOOR
FUNCTION SETTING
Ceiling switching function (standard/high ceiling)
z
Also delivers air to high ceilings by selecting the mode and raising the air flow according to the
height of the ceiling.
Standard ...Operates at normal air flow.
Mode 1 ...Air flow becomes greater than normal.
Auto restart
z
The units restart automatically when the current was returned even when there was a power
interruption during operation.
Room temperature sensor switching
z
Switches from room temperature judgment by room temperature sensor attached to indoor
unit body to room temperature judgment by room temperature sensor attached to wired remote
controller.
Cooling room temperature correction
z
Heating room temperature correction
z
1
5
4
3
Steps
Swing: Cooling , Dry and Fan mode
Swing: Heating and Fan mode
Fresh-air
OUTDOOR
Up and Down Swing
2
3
4
5
5 steps selectable
- (02-09) -