Asr Network Configuration; Scanner Replacement Procedure - Datalogic DS6300 Reference Manual

Hide thumbs Also See for DS6300:
Table of Contents

Advertisement

MAINTENANCE
The ASR procedure restores only a part of the system parameters: common slave
parameters (Code Selection and Reconstruction).
The Master must be prepared at the time of installation in order for this procedure to work
correctly.

10.3.1 ASR Network Configuration

1. On the Master scanner, check the Modify & Backup Lon Slave Scanner
Configuration parameter in Genius™ and configure the Lonworks Slave Scanner
Common Parameters (Code and Reconstruction Parameters).
2. Enable the ASR procedure through the Enable A.S.R. parameter in the Master
configuration.
3. Send the configuration to the Master EEPROM to force the Slave Operating Mode, Code
Reading Symbologies and Reconstruction parameters.
Now the Slave scanners are configured through the Master (ASR parameters stored in
the Master) and the ASR procedure is implemented.
4. Save this configuration to file (.ddc).

10.3.2 Scanner Replacement Procedure

The ASR procedure requires replacing one scanner at a time.
NOTE
Slave
1. Power down the entire system.
2. Replace the Slave scanner with a new one (default settings).
3. Power up the system and wait for initialization.
Master
1. Load the saved configuration from file (.ddc) to a new Master scanner.
2. Power down the entire system.
3. Replace the old Master scanner with the new one.
4. Power up the system and wait for initialization.
The ASR works only if both the Master and Slave devices have software
6.40 or later.
NOTE
10