Datalogic DS6300 Reference Manual page 96

Hide thumbs Also See for DS6300:
Table of Contents

Advertisement

9
Display Visualization
The first line of the display shows the read code and Good Read percentage. Possible
suspending commas at the end of the code mean that the code is too long to be
displayed.
The second line of the display indicates the value of the focus position according to the
table below. The indications "Too Near" or "Too Far" are represented for values outside
the focus range.
Graphical Visualization
A
|---^----------|
B
N-------------|
C
|--------------F
CodeRead... 100%
|------^------------------|
Figure 96 – Graphical Visualization
5) Rotate the focus adjustment screw to reach the desired focus position. The display is
refreshed with the new values;
6) Press the ▲ (up arrow) key to exit the Test Mode;
7) Use the ▲ (up arrow) and ▼ (down arrow) key to select the "Exit" item, then press the
ENT (enter) key to confirm. The scanner exits the Main Menu and returns to its current
operating mode.
The reader display shows the focus position only when the laser beam is
activated.
NOTE
It is possible to visualize the focus position and the reading percentage on the terminal tool
provided by the Genius™ configuration program (see Genius™ Help On-Line for details).
3
To avoid breakage, do not use excessive force when rotating the focus adjustment screw.
80
 where ^ indicates the focus position
 where N indicates that the focus
position is "Too Near"
 where F indicates that the focus
position is "Too Far"
3
Figure 98 - Focus Adjustment Screw
DS6300 REFERENCE MANUAL
Numerical Visualization
Fxxx
 where xxx ranges from 000 to 100
TooNear
Fxxx*
 where xxx is greater than 100
CodeRead... 094%
F034
Figure 97 – Normal Visualization