Datalogic DS6300 Reference Manual page 101

Hide thumbs Also See for DS6300:
Table of Contents

Advertisement

READING FEATURES
DS6300-100-0XX - Resolution: 0.30 mm/12 mils
0
8
0
20 25
12
30
10
25
8
20
6
15
4
10
2
5
0
0
-5
-2
-10
-4
-15
-6
-8
-20
-10
-25
-12
-30
(in)
(cm)
Figure 104 - Standard Model 0.30 mm / 12 mils Reading Diagram
CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
Pitch angle = 0°
Skew angle = 10° - 20°
Tilt angle = 0°
Note: (0,0) is the center of the laser beam output window.
10
12
14
16
30
35
40
Focus
Position = 0
Focus
Position = 60
18
20
22
24
45
50
55
60
65
Focus
Position = 40
26
28
30
32 34
70
75
80
85
9
(in)
(cm)
85

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents