SOFTWARE CONFIGURATION
8.2.2 Genius™ Network Setup Through Master
Network Setup allows configuring your Local Lonworks Network through the Master using
Genius™.
Three different procedures are available to define the number of network slave scanners,
their label and address according to two main conditions:
Condition
Unknown Slave Addresses
Known Slave Addresses
The Network Setup procedure as described requires Genius™ software
version 1.06 or later. In addition, the Net-Autoset procedure requires
scanner software version 6.40 or later.
NOTE
1. The first operation to perform is the configuration of your scanner as "Master" from the
Local Device Network Settings item in the Device Menu, see figure below:
Available Procedure
Net-Autoset
Network Wizard
Express Network Setup
Figure 93 – Local Device Network Settings
Feature
automatically assigns random addresses to
slave or Stand Alone scanners.
customizes the network (slave label and
address definition and physical identification
of a specific slave within network), updates
configuration to a file and makes it ready to
be sent to the Master.
automatically performs all the operations of
the Network Wizard apart from the physical
identification of a specific slave scanner.
8
67