LONWORKS CONNECTIONS
The following diagram represents the connection between a DS6300 working as master and
a DS6300 working as a slave reader.
The cable shield for LON A/B is connected to pin1 - CHASSIS.
The maximum current to be propagated to the Slave readers through the
Master is 2 A. For this reason, it is suggested to use a 24 Vdc power supply
capable of supplying up to three readers (Master + 2 Slaves).
CAUTION
The following diagrams represent different network terminations using the BT-6000 Lonworks
terminator. In Figure 73 the BT-6000 terminator is indicated by the
figure below shows its electrical circuit in details:
Master
VS_I/O
4
5
REF_I/O
3
LON A
7
LON B
8
CHASSIS
1
VS
9
GND
2
= male connector
= female connector
Figure 71 – DS6300 Master/Slave Lonworks Connection
Figure 72 – BT-6000 Electrical Circuit
Slave
4
5
3
7
8
1
CHASSIS
9
AWG 16
2
AWG 16
5
element, while the
51