Datalogic DS6300 Reference Manual page 68

Hide thumbs Also See for DS6300:
Table of Contents

Advertisement

5
The diagram below represents the termination of a DS6300 (Master/Slave model) working as
master by means of the BT-6000.
The diagram below represents the termination of a DS6300 (Master/Slave model) working as
slave by means of the BT-6000 terminator.
The diagram below represents the connection between a DS6300 Fieldbus model, which
always works as master, and a Master/Slave model working as a slave reader.
Figure 75 – DS6300 Fieldbus Master to Slave Lonworks Connection
The Fieldbus master is internally terminated.
52
Master
VS
9
VS_I/O
6
LON A
7
LON B
8
GN D
2
REF_I/O
3
= male connector
= female connector
Figure 73 – DS6300 Master Termination
Slave
LON A
7
LON B
8
= male connector
= female connector
Figure 74 – DS6300 Slave Termination
Fieldbus Master
VS_I/O
4
5
REF_I/O
3
LON A
7
T
LON B
8
CHASSIS
1
VS
9
GND
2
= male connector
= female connector
DS6300 REFERENCE MANUAL
BT-6000 Female Side
9
6
7
T
8
2
3
BT-6000 Male Side
7
T
8
Slave
4
5
3
7
8
1
CHASSIS
9
AWG 16
AWG 16
2

Hide quick links: