Installation Requirements - Contec IPC-BX950T1-DC500 User Manual

Ipc series
Table of Contents

Advertisement

Installation Requirements

Be sure that the ambient temperature is within the range specified in the installation environment
requirement by making space between the product and device that generates heat or exhaust air.
IPC-BX950T1-DC5xx , IPC-BX950T2-DC4xx
Installable directions at ambient temperature 0°C - +50°C
: (2) Vertical installation (power connector is downside)
Installable directions at ambient temperature 0°C - +45°C
: All type of installation other than above (including diagonal installation)
IPC-BX950T3-DC5xx
Installable directions at ambient temperature 0°C - +45°C
: (2) Vertical installation (power connector is downside)
Installable directions at ambient temperature 0°C - +40°C
: All type of installation other than above (including diagonal installation)
(2)
(1)
*
Connector
Figure 3.6. Installation Orientation
CAUTION
Note that even though the ambient temperature is within the specified range, an operational
malfunction may occur if there is other device generating high heat; the radiation will influence the
product to increase its temperature.
IPC-BX950T1 / IPC-BX950T2 / IPC-BX950T3 User's manual
Ceiling
(6)
Floor
3. Hardware Setup
(4)
(3)
Connector
(5)
17

Advertisement