No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO., LTD. CONTEC CO., LTD. makes no commitment to update or keep current the information contained in this document.
Table of Contents Copyright ..............................i Trademarks .............................. i Table of Contents............................ ii INTRODUCTION Features .............................1 Customer Support ............................2 Web Site............................2 Limited One-Year Warranty ........................2 How to Obtain Service ..........................2 Liability..............................2 Safety Precautions ...........................3 Safety Information..........................3 Handling Precautions ........................3 OVERVIEW Specifications............................7 External Dimensions ..........................10 EACH COMPONENT FUNCTION...
I/O, stereo sound function as standard. Installed supporting I/F drivers as standard. XIP & memory loading boot function enabling quick startup in shortest about 10 seconds. Installed "CONTEC Manager" for system development support (such as scheduling, FTP server, autorun). IP65/NEMA4 compliant front panel.
You can download updated driver software and differential files as well as sample programs available in several languages. Note! For product information Contact your retailer if you have any technical question about a CONTEC product or need its price, delivery time, or estimate information. Limited One-Year Warranty CONTEC products are warranted by CONTEC CO., LTD.
1. Introduction Safety Precautions Understand the following definitions and precautions to use the product safely. Safety Information This document provides safety information using the following symbols to prevent accidents resulting in injury or death and the destruction of equipment and resources. Understand the meanings of these labels to operate the equipment safely.
Page 9
1 Introduction This product is not intended for use in aerospace, space, nuclear power, medical equipment, or other applications that require a very high level of reliability. Do not use the product in such applications. If you utilize this product in such usages where high reliability and safety are required as on the trains, vessels, automotives or crime- or disaster-prevention devices, contact your retailer.
Page 10
Moreover, when power supply OFF is done while writing it, data in flash memory (NFDISK) might be damaged. * CONTEC accepts your request for replacing each consumable in the PANECON-PC as a request for repair (at an additional cost). If installed horizontally (with the LCD panel face up), the unit should be used at an ambient operating temperature of not greater than 30 degrees centigrade.
2. Overview 2. Overview Specifications Functional Specifications Table 2.1. Functional Specifications Type IPC-PT/SV10DC1-4E LCD type LCD type 6.5-inch TFT color LCD (640 x 480) Number of colors 65536 Touch panel Resolution 4096 x 4096 (emulated in 640 x 480 mode) Detection method Analog resistive Type SH-4 HD6417751RBP 240MHz...
Page 13
2 Overview Installation Environment Requirements Table 2.2. Installation Environment Requirements Item Specification Ambient specifications Operating temperature 0 - 50ºC Storage temperature -10 - 60ºC Operating Humidity 20 - 85%RH(no condensation) Floating dust particles Not to be excessive Corrosive gases None Line-noise Line noise AC line: 2kV (Using the AC adapter IPC-ACAP12-01)
3. Each Component Function 3. Each Component Function Component Locations CF card (NFDISK) cover * * * * Function switch USER LED POWER LED DIP-SW(SW2) cover POWER LED RESET PCMCIA COM2 COM1 DIP-SW(SW1) SPERKER +12VDC power connector AC adapter jack USER LED * Refer to the software manual for the function switches, POWER LED and Figure 3.1.
Page 17
3 Each Component Function Table 3.1. Component Identification Component Function Function switch Refer to the software manual. POWER LED Power supply ON display LED USER LED USER LED (3-colors, opened to user) +12VDC power connector +12V power supply input (3P phoenix contact) AC adapter jack +12V power supply input (AC adapter: for IPC-ACAP12-01) PCMCIA...
3. Each Component Function Serial Port Interface (COM1, COM2) The PANECON-PC is equipped with two RS-232C-compliant serial port connectors (Serial Port 1: COM1 and Serial Port : COM2). Table 3.2. COM1/COM2 Serial Port Inter Connector Main unit connector D-SUB 9-pin (Male) No.4-40UNC Inch screw Pin no.
3 Each Component Function Ethernet (UTP) Table 3.3. Ethernet connector (RJ-45) Connector type RJ-45 LINK Function Pin No. Singal name Transmitted data (+) output Transmitted data (-) output Received data (+) input Not connected N.C. Not connected N.C. Received data (-) input Not connected N.C.
3. Each Component Function PCMCIA (PCMCIA) × × PCMCIA compliant card slots are provided [TYPE II 2 (TYPE III 1) size]. Slot 1 Slot 2 ↓ Front (LCD) side Figure 3.2. Slot Numbers and Locations CAUTION A type III card should be inserted into slot 2. Power Supply to the Card The voltage that can be used and the current capacity of each slot are as shown below: Table 3.4.
3 Each Component Function General-purpose I/O ports (I/O) The unit has four channels of general-purpose insulated I/O port. Refer to the bundled CD-ROM(CONTEC SDK for CE420) for programming this ports. Table 3.6. General-purpose I/O ports connector ↓ Front (LCD) side Pin No.
Page 22
3. Each Component Function Specifications [Input section] Input specification : Photocoupler-insulated current drive input Input resistance : 3kΩ Number of input signals Input protection circuit : Reverse-connection protection diode Input response time : Within 100μsec External circuit power supply : 12 - 24VDC(±10%) [Output section] Output specification : Photocoupler-insulated open-collector output...
3. Each Component Function AC adapter jack This jack accepts the optional AC adapter [IPC-ACAP12-01]. Do not plug any other AC adapter into the AC adapter jack. Table 3.7. AD adapter jack pinouts Pin No. Name +12V input CAUTION When the AC adapter jack is used, the unit requires no power input via the power input connector. As the AC adapter, be sure to use the option [IPC-ACAP12-01].
3 Each Component Function External Speaker Output Terminal (SPK) Connector type: HSJ1456-010330 (HOSIDEN) Table 3.9. External Speaker Terminal Remarks Pin no. Signal Speaker(Right) Analog signal(R) Speaker(Left) Analog signal(L) 1pin 2pin R Analog signal 3pin L Analog signal Applicable connector: Small jack of φ3.5mm Full-scale output level 1.0Vrms(Typ.) Touch Panel The PANECON-PC is equipped with an analog touch panel that enables keyboard-less, mouse-less...
DIP switch for Opened SW to user (SW1) SW1 is a general-purpose switch available for use by the application. Refer to the bundled CD-ROM(CONTEC SDK for CE420) for details on how to use this DIP switch. Figure 3.5. DIP switch DIP switch for Setup of OS operation (SW2) This switch sets OS operation.
3 Each Component Function LED display POWER USER Figure 3.7. LED display POWER LED (Side and front view) : Two colors (green/orange) The same function with the POWER LED on the front side of this unit. It turns on orange or green when starting. After it starts, it always turns on green. Turning on Orange: When internal NFDISK drive is read and written.
4. Hardware Setup 4. Hardware Setup Installation Requirements To maintain the ambient temperature within the installation environment requirement range, provide a gap of 30mm or more between the main unit and any adjacent equipment. Panel 30mm or more (Top view) 30mm or more 30mm or more (Side view)
Back light exchange The backlight used in the LCD module has a limited life. When it expires and requires replacement, contact your local CONTEC sales office. Attaching the Fitting Used to Attach to the Main Unit (1) Hold the main unit from the outside of the panel.
4. Hardware Setup Panel cut dimensions Figure Panel thickness range 1.6 - 7mm [mm] Figure 4.4. Panel cut dimensions figure CAUTION Use a panel with a thickness in the range 1.6 - 7mm. Removing the cover for OS operation setup DIP switch (SW2) When setting the SW2, you need to remove the back cover.
4 Hardware Setup AC adapter removal prevention fitting (1) Insert the plug of AC adapter. (2) Use the screw to fasten the fitting. Figure 4.6. Attaching the code removal prevention fitting Hardware Manual...
3-9-31, Himesato, Nishiyodogawa-ku, Osaka 555-0025, Japan Japanese http://www.contec.co.jp/ English http://www.contec.com/ Chinese http://www.contec.com.cn/ No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO., LTD. [07092008] [06162004] Management No. A-46-875 [07092008_rev5] Parts No.
Need help?
Do you have a question about the IPC-SV10DC1-4E and is the answer not in the manual?
Questions and answers