[C2]
Assigning the Remote Control Functions
(SET UP 2) — REMOTE Menu

Overview

The remote control functions are set with the
REMOTE menu. With this monitor, both serial remote
control (REMOTE 1) and parallel remote control
(REMOTE 2) are possible.
The following settings can be made with the REMOTE
menu.
• Settings for the serial remote control (REMOTE
1) (REMOTE 1 CONFIG menu)
An address number (MONITOR ADDRESS) and
group number (GROUP ADDRESS) can be assigned
to the monitor connected to the serial REMOTE 1
connector.
The BVM-xxE/F/G and BVM-Dxx series monitors
can be connected.
• Settings for the parallel remote control (REMOTE
2) (REMOTE 2 CONFIG menu)
Functions can be assigned to the pins of the
REMOTE 2 connector.
• ON/OFF setting for the parallel remote control
(REMOTE 2) (REMOTE 2 menu)
Priority order of the remote control functions
It is possible to simultaneously use the BKM-10R/11R
Monitor Control Unit, REMOTE 1, and REMOTE 2
for control. The last commands have priority.
There is no priority order between commands from
REMOTE 1 and the BKM-10R/11R control panel.
Process for the parallel remote control
(PARALLEL REMOTE)
1
All 8 pins are scanned.
2
Pins from 8 through 1 are scanned for process of
the channel setting, and the first changed pin is
selected.
3
Pins from 8 through 1 are scanned for other
precesses, and the changed pins are selected.
Example of channel selection (when CH1 is assigned
to the 1 pin and CH2 is assigned to the 2 pin)
CH1(1 pin)
OFF
ON
CH2(2 pin)
OFF
ON
OFF
-
CH2
CH1
34
OFF
ON
OFF
ON
OFF
CH2
CH1
CH2
About monitor address and group numbers
The BKM-10R/11R Monitor Control Units are able to
control up to 32 monitors connected via serial remote
connector (using the REMOTE 1 connector). By
giving each monitor a monitor address and group
number, it is possible to control just a specific monitor
or monitor group.
With the REMOTE 1 CONFIG menu, each monitor
can be set with a monitor address and group number,
between 1 and 99.
The ADDRESS menu is used to select a particular
monitor or group by entering a monitor number or
group number.
For information about the ADDRESS menu, see "Selecting
the Monitor to Control — ADDRESS Menu" on page 55.
Note
The address number must differ from one monitor to
another. If two or more monitors have the same
address number, an operation error occurs.