D
Assigning the Remote Control Functions
— REMOTE Menu

Overview

The remote control functions are set with the
REMOTE menu. With this monitor, both serial remote
control (SERIAL REMOTE) and parallel remote
control (PARALLEL REMOTE) are possible.
• Settings for the serial remote control (SERIAL
REMOTE)
An address number (MONITOR ADDRESS) and
group number (GROUP ADDRESS) can be assigned
to the monitor connected to the SERIAL REMOTE
connector.
• ON/OFF setting for the parallel remote control
(PARALLEL REMOTE)
• Settings for the parallel remote control
(PARALLEL REMOTE)
Functions can be assigned to the pins of the
PARALLEL REMOTE connector.
Priority order of the remote control functions
It is possible to simultaneously use the BKM-10R/11R
Monitor Control Unit, SERIAL REMOTE, and
PARALLEL REMOTE for control, but commands
from PARALLEL REMOTE have priority. Therefore,
it is impossible for the BKM-10R/11R or SERIAL
REMOTE to change items set by PARALLEL
REMOTE.
There is no priority order between commands from
SERIAL REMOTE and the BKM-10R/11R control
panel.

Structure of the REMOTE Menu

Level 1
SERIAL REMOTE D1
MONITOR ADDRESS
GROUP ADDRESS
PARALLEL REMOTE
PARALLEL REMOTE CONFIG D2
PARALLEL REMOTE 1 and 2 are connected
parallel inside the unit, therefore, there is no priority
order between them.
About monitor address and group numbers
It is possible to control up to 32 monitors connected
via serial remote connector (using the SERIAL
REMOTE connector). By giving each monitor a
monitor address and group number, it is possible to
control just a specific monitor or monitor group.
With the SERIAL REMOTE menu, each monitor can
be set with a monitor address and group number,
between 1 and 99.
The ADDRESS menu is used to control the monitors
which are connected by the serial remote connectors.
For information about the ADDRESS menu, see "Selecting
the Monitor to Control — ADDRESS Menu" on page 45(E).
Note
The address number must differ from one monitor to
another. If two or more monitors have the same
address number, an operation error occurs.