1-4-6. Assigning the Remote Control Functions
The remote control function is available either in STANDARD
PARALLEL or CONFIGURE PARALLEL mode.
The mode change is achieved through the REMOTE CONTROL
menu operation.
The SERIAL REMOTE option mode in the REMOTE CONTROL
menu is provided for future use. If you inadvertently select it, cancel
the REMOTE CONTROL menu by pressing the ESC button.
STANDARD PARALLEL
mode
The remote control function is set to the STANDARD PARALLEL
mode and the following functions are assigned to the pins of the
REMOTE connector at the factory.
Function
INPUT
__ SYNC
INT
A
EXT
INT
B
EXT
VITC OFF
VITC HOLD
TALLY ON
S: Short~circuit with pin No.a
0: Open
-: Either S or O
®
0)
0 ®
®
®
@
(i)
®®
Pin assignment
..
.
·.
.
.
.
MODE
1
2
..
AUTO
0
0
MONO
s
0
AUTO
0
0
MONO
s
0
AUTO
0
s
MONO
s
s
AUTO
0
s
MONO
s
s
-
-
-
-
-
-
Pin No .
.
.
3
4
5
6
-
0
-
-
-
0
-
-
-
s
-
-
-
s
-
-
-
0
-
-
-
0
-
-
-
s
-
-
-
s
-
-
-
-
-
s
-
-
-
0
s
-
-
-
The assigned function can be controlled by short-circuiting the
corresponding pin with pin 8.
Note that pin 3 is fixed to TALLY and pin 8 is fixed to GND.
The remote control operations have priority over the respective
buttons and switches of the monitor.