B Adjusting the Color Temperature — COLOR TEMP ADJ Menu
[B12] PROBE menu
Select the probe for color temperature adjustment.
SONY BKM-14L...: Use the BKM-14L.
k[B121]
GRASEBY SLS 9400...: Use the SLS 9400.
k[B122]
MINOLTA CA-100...: Use the CA-100. k[B122]
PHILIPS PM 5639...: Use the PM 5639. k[B122]
THOMA TF6...: Use the TF6. k[B122]
• If you cannot execute an ADJUST or ANALYZE
menu operation when using the Sony BKM-14L
probe, try again after disconnecting and reconnecting
the probe.
• When using the Thoma TF6 probe, set the TF6
PRINT menu to off.
[B121] SONY BKM-14L menu
Select the BKM-14L operation.
ADJUST... : Perform automatic color temperature
adjustment. k[B1211]
ANALYZE: Display readout values on the screen.
k[B1212]
[B1211] ADJUST menu
To start adjustment, proceed as follows.
When you use the previously adjusted values for
adjustment, you can make start adjustment by selecting
START without performing step (1) and step (2).
(1) Select either D65, D61 or D93.
Rather than selecting D65, D61 or D93, you may
instead enter the values of the CIE 1931 color
system x and y coordinates.
(2) Enter values for LOW LIGHT and HIGH LIGHT.
(3) Select START.
START: Start adjustment. k[B12111]
X: Enter the x coordinate.
Y: Enter the y coordinate.
LOW LIGHT (20IRE): Enter the luminance (cd/m
for low light.
HIGH LIGHT (100IRE): Enter the luminance (cd/
m
2
) for high light.
D65: Use D65 setting.
D61: Use D61 setting.
D93: Use D93 setting.
26
[B12111] START menu
The following message appears. Perform operation
according to the message to start adjustment.
SET PROBE ON CRT
PRESS ENTER
Adjustment starts when the probe is placed against the
center of the screen and the ENTER or Ent button is
pressed.
[B1212] ANALYZE menu
The following message appears. Perform operation
according to the message to enable the BKM-14L to
read the color system and luminance value.
SET PROBE ON THIS CRT
PRESS ENTER
Attach the BKM-14L on the center of the CRT and
press the ENTER or Ent button. k[B12121]
Once the BKM-14L has carried out calibration, the
BKM-14L can start analyze the monitor's
performance.
[B12121] SET PROBE ON THIS CRT menu
Display the color system and luminance readout values
from the BKM-14L system at the bottom of the CRT.
X: xxxx: Display the x coordinate of the color system.
Y: xxxx: Display the y coordinate of the color system.
L: xxxx: Display the luminance value.
[B122] GRASEBY/MINOLTA/PHILIPS/THOMA
menu
The forth and lower levels of [B122] are the same as
those of the fifth and lower levels of [B1211]. Refer to
[B1211] and [B12111].
[B13] COPY FROM menu
2
)
Select the source to be copied from.
OTHER VALUE... : Copy data from another channel
or from common data. k[B131]
OTHER MONITOR... : Copy data from a BVM-F24
series monitor. k[B132]
MEMORY CARD... : Copy data from a monitor
memory card. k[B133]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trinitron bvm-f24aTrinitron bvm-f24uTrinitron bvm-f24j

Table of Contents