4.4.9 Partial file recall

Partial file recall can be used to undo changes on a group of video parameters. Groups that can
be recalled are Gain, Filters, Detail, Exposure Time, Color, Black, Flare, Skin, Gamma and Knee.
To recall a group of parameters press and hold the FILES button and at the same time press
the button for the function group you want to recall. All functions of this group are restored to
the user's reference settings.
While the FILES button is pressed the last recalled or restored file is displayed on the menu
panel.
Note
Note
A partial recall of the Gain function set will also recall the RGB Gain values and a partial recall of
the Black function set will also recall the RGB Black values and the master black value.

4.4.10 Recalling standard files

– Push the RECALL STD. button to open the menu.
– Select either a factory or a customer file for recall.
– Select RECALL.
Menu
Recall
Standard
40
Selections
Function
RECALL
Recall standard file
STD CUST/
Select factory or customer file
FACT
to recall
-
-
Chapter 4 - Operation
Level
Possible values
S
S
Factory, Custom