Figure B-4, Battery Bank Wiring Examples (24-Volt) - Magnum Energy RD-E Series Owner's Manual

Modified sine wave inverters/chargers
Table of Contents

Advertisement

Series String
(12 VDC + 12 VDC)
24 volt battery bank (one string of two 12-volt batteries wired in series)
Series String
(6 VDC + 6 VDC
+ 6 VDC + 6 VDC)
24 volt battery bank (one string of four 6-volt batteries wired in series)
Parallel String (100 AH + 100 AH)
Series String
(12 VDC + 12 VDC)
Series String
(12 VDC + 12 VDC)
(two strings of two 12-volt batteries wired in series and connected in parallel)
Parallel String (200 AH + 200 AH)
Series String
(6 VDC + 6 VDC
+ 6 VDC + 6 VDC)
Series String
(6 VDC + 6 VDC
+ 6 VDC + 6
VDC)
(two strings of four 6-volt batteries wired in series and connected in parallel)

Figure B-4, Battery Bank Wiring Examples (24-volt)

© 2010 Magnum Energy, Inc.
12 VDC
battery
(100 AH)
6 VDC
6 VDC
battery
battery
(200 AH)
(200 AH)
12 VDC
battery
(100 AH)
12 VDC
battery
(100 AH)
24 volt battery bank
6 VDC
6 VDC
battery
battery
(200 AH)
(200 AH)
6 VDC
6 VDC
battery
battery
(200 AH)
(200 AH)
24 volt battery bank
Appendix B - Battery Information
overcurrent
protection
12 VDC
battery
(100 AH)
6 VDC
6 VDC
battery
battery
(200 AH)
(200 AH)
overcurrent
protection
12 VDC
battery
(100 AH)
12 VDC
battery
(100 AH)
6 VDC
6 VDC
battery
battery
(200 AH)
(200 AH)
6 VDC
6 VDC
battery
battery
(200 AH)
(200 AH)
to 24 VDC
inverter
(total capacity
= 100 AH)
overcurrent
protection
to 24 VDC
inverter
(total capacity
= 200 AH)
to 24 VDC
inverter
(total capacity
= 200 AH)
overcurrent
protection
to 24 VDC
inverter
(total capacity
= 400 AH)
Page 46

Advertisement

Table of Contents
loading