Guard Time (3 Or More Incorrect Code Inputs); Closing The Lock; Changing Codes (P); Table 25: Opening With Alarm Code - Kaba Combi B 30 Operating Instructions Manual

With metal input unit
Hide thumbs Also See for Combi B 30:
Table of Contents

Advertisement

Opening process:
Description
Enter a modified valid opening code as an alarm code
1.
(ID = 00 to 30 or 95, X = the first 5 positions of the programmed 6-digit combination for the corr. ID number,
Y = increased by 1 or decreased at the 6th position of the combination mentioned above)
2. Turn the actuating knob within 4 seconds through 90° clockwise to the stop

Table 25: Opening with alarm code

If the Incorrect code signal is output after the code input, the entry must be repeated completely. After 3 incorrect inputs
the lock switches to guard time in this case as well (see chapter 10.5)
Double code:
With the activated double code it is sufficient to enter both codes as alarm codes in order to activate the silent alarm.
However, the alarm is activated only if both codes required for opening have been entered completely.
10.5

Guard time (3 or more incorrect code inputs)

After 3 incorrect inputs the lock switches to a 1-minute guard time. For each further incorrect code input the guard time is
extended to 2, 4, 8 and finally to 16 minutes. During the entire guard time no code input is possible. The guard time can onl y be
omitted by means of the inspection key, however, it cannot be deleted (see chapter 11.1). Only after the guard time has
elapsed, the lock can be opened as described in chapter 10.1 to 10.4.
10.6

Closing the lock

Turn the actuating knob counterclockwise through 90° to the stop
If there is a boltwork available (usually recognized due to an additional rotary handle on the secure storage unit), it has to
be locked, first, after the door has been closed. Only after that the lock can be closed.
Secure closing of the lock has to be tested by trying to rotate the knob at the input unit. The knob must not be turned
through more than approx. 45°.
10.7

Changing codes (P)

Everyone is authorised to change his/her own code any time. The master is not authorised to change the user or courier code.
But he/she can activate, block, release and delete codes.
After changing the previous code is no longer valid and the new code must be used. The function of the new code must be
tested by opening the lock with the secure storage unit open (see chapter 10.1)!
Description
1. Press
and enter the code to be changed
(ID [00 to 30 or 95], X = programmed 6-digit combination for the corr. ID number)
2. Enter the new code
(ID the same as in 2, Y = new 6-digit combination for this ID number)
3. Confirm the new code with

Table 26: Changing code

The entire procedure has to be repeated in case of the following errors:
If the Incorrect code signal is displayed according to 1. after the entry of the code to be changed, the code has been
entered incorrectly or not assigned and, thus, cannot be changed.
If the Incorrect code signal is displayed after the first new code input as described in 2., the ID does not match the ID in
step 1. The ID must always be kept, even in case of code modification.
If the Incorrect code signal is displayed after the second attempt to enter the new code as shown in 3., then the two
codes entered in 2. resp. 3 do not match.
Version 2013-08-10
Page 42 of 48
and
and
Operating instructions 82132/3xxx CB 30
.
. Code input is not required.
and
and
2x
2x
3x
3x
2x
3x
3x
2x
3x
3x
2x 2x
3x
3x

Advertisement