Page 1
Kaba digital cylinder User manual Doc. no.: k1evo805en-2012-09...
Page 2
Tiverton Devon Austria Switzerland EX16 655 www.kaba.co.uk www.kaba.com www.kaba.com This documentation may not be reproduced in any way or otherwise used without the written consent of Kaba AG. Kaba® is a registered trademark of Kaba AG copyright by Kaba AG 2012...
The operator must retain this user manual and the additional documentation for the entire service life of the system. Validity This user manual describes the Kaba evolo system mechatronic locking cylinder, known as the Kaba digital cylinder. Target group This user manual is aimed at specialist personnel, to enable installation, commissioning and maintenance of this product.
45. In order to simplify the user manual for the reader, the mechatronic locking cylinder Kaba digital cylinder is referred to as "digital cylinder" for short, and the programming device Kaba Programmer 1460 is referred to as "programmer" for short.
• Do not open, drill through or squash lithium batteries. • Do not burn lithium batteries or expose them to high temperatures. • Do not short circuit lithium batteries. • Do not recharge lithium batteries. • Do not connect lithium batteries in parallel. Kaba digital cylinder k1evo805en-2012-09...
The cylinder must protrude no more than 3 mm beyond the doorplate. The whereabouts of identification media (keys, badges, etc.) must always be known to ensure only authorised personnel gain access. If identification media are lost, the authorisation data must be blocked/deleted from all cylinders immediately. k1evo805en-2012-09 Kaba digital cylinder...
Disposal in Germany Kaba devices are registered as "B2B" in the Register of Used Electrical Equipment [Elektro-Altgeräte Register]. Kaba guarantees the return and disposal of the product. Do not dispose of used batteries with household waste Used batteries must be disposed of in line with the governmental and local regulations.
EN 179/1125 class 7 Corrosion DIN EN 1670 class 3 Key: The temperature range depends on the battery manufacturer's specifications. depending on the configuration Type 1439 and 1539 starting from a total length of 85 mm Kaba digital cylinder k1evo805en-2012-09...
(In accordance with certificate from the lock manufacturer.) Use of the digital cylinders in older panic locks must be checked. No modifications of any type are permitted, with the exception of those detailed in this user manual. k1evo805en-2012-09 Kaba digital cylinder...
Cylinder housing Bayonet disc O-ring, Ø 15 x 1 mm Internal knob MC-Insert Hexagonal screw Dimensions The dimensions stated are also valid for the 22 mm round profile cylinder. Dimension drawing 1435 Standard (17 mm profile cylinder) Kaba digital cylinder k1evo805en-2012-09...
Page 14
With the cylinder lengths, leave a gap of at least 1 mm between the door furniture and the door knob, so that the service tool can be used on the door knob. The anti-panic digital cylinder, type 1537 round profile, has a continuous bridge on the inside (LB). k1evo805en-2012-09 Kaba digital cylinder...
1. Hold an authorised user medium in front of the digital cylinder, as shown. 2. The short acoustic signal (if activated) and the optical green display indicate that access is authorised. 3. Open the lock by turning the door knob. Kaba digital cylinder k1evo805en-2012-09...
1 x short green * The mechatronics unit engages, the lock can be opened or closed. Hold up unauthorised 4 x short 4 x red medium. The outer door knob turns without engaging, the lock cannot be opened or closed. k1evo805en-2012-09 Kaba digital cylinder...
Page 17
System monitoring and check that unit has engaged Acoustic signal Optical display Hold up an authorised medium. 8 x short 8 x short red The mechatronics unit does not engage! (See Fault rectification on page 44) Kaba digital cylinder k1evo805en-2012-09...
(with or without profile cutout). Tools required • Kaba service tool, item number 1430-25 • Hexagonal screw, hex 1.5 mm, item number 1430-55 • Cross-head screwdriver for forend locking stud, size PZ 2...
3 mm from the door furniture. The anti-panic digital cylinder, type 1537 round profile, has a continuous bridge on the inside (LB), meaning that a recess in the door furniture is necessary. Kaba digital cylinder k1evo805en-2012-09...
4. From the outer side of the door, push the digital cylinder through the door furniture and the lock. 5. Position the forend locking stud in the lock and tighten it slightly. 6. Push the inner door knob onto the cylinder housing. k1evo805en-2012-09 Kaba digital cylinder...
Page 21
It must be possible to open the lock with the lever handle in all cam rest areas. For emergency exit or panic door locks, it is vital that the specifications of the lock and door furniture manufacturers are observed. Kaba digital cylinder k1evo805en-2012-09...
Page 22
The digital cylinder in the version without inside knob must be programmed prior to the function check. Following this, hold an authorised medium in front of the digital cylinder and carry out the function test by turning the outer door knob (turning knob). k1evo805en-2012-09 Kaba digital cylinder...
4. Attach the service tool to the securing shackle from below. Push out the securing shackle and remove the door knob module. 6. Using the hexagonal key, loosen the screw from the inner door knob. 7. Remove the inner door knob. Kaba digital cylinder k1evo805en-2012-09...
Page 24
9. Align the cam flush with the cylinder housing. 10.Push the cylinder housing through the lock from the inner side of the door. 11.Position the forend locking stud in the lock and tighten it slightly. k1evo805en-2012-09 Kaba digital cylinder...
Page 25
O-ring is not damaged in the process. 16.Push the securing shackle into the electronical module from above, to the end stop position. The electronical module and the cylinder housing are now firmly connected. Kaba digital cylinder k1evo805en-2012-09...
Page 26
Installation User manual The outer door knob can only be attached in one position. The Kaba logo and the upper surface of the battery compartment must be on the same side. 17.Insert the battery. See page 28. 18.Push the outer door knob over the electronical module.
Page 27
The digital cylinder in the version without inside knob must be programmed prior to the function check. Following this, hold an authorised medium in front of the digital cylinder and carry out the function test by turning the outer door knob (turning knob). Kaba digital cylinder k1evo805en-2012-09...
1. Position the service tool on the inner side of the outer door knob. 2. Turn the service tool clockwise and unlock the outer door knob. 3. Remove the outer door knob. 4. Remove the existing used battery. k1evo805en-2012-09 Kaba digital cylinder...
Page 29
Assemble the outer door knob The outer door knob can only be attached in one position. The Kaba logo and the upper surface of the battery compartment must be on the same side. 6. Push the outer door knob over the door knob module.
If a user medium is lost, the authorisation data of the lost identification medium must be blocked/deleted from all cylinders immediately. (Enter in the blacklist in the Kaba evolo Manager software, or delete all user media with the relevant master and then reprogram all user media).
B masters as wished. For example, a B1 master only manages 50 users whilst another master, B2, manages up to 3950 users. 7.2.1 Programming A/B and B structures A/B structure A master B master B structure User media Kaba digital cylinder k1evo805en-2012-09...
Page 32
End of programming mode Beeeep 4. Hold the A master medium in front of the outer door knob for approx. 1 s. If no master medium is held up within 10 seconds, programming mode 1 x long ends automatically. k1evo805en-2012-09 Kaba digital cylinder...
Page 33
End of programming mode Beeeep 4. Hold the B master medium in front of the outer door knob for approx. 1 s. If no master medium is held up within 10 seconds, programming mode 1 x long ends automatically. Kaba digital cylinder k1evo805en-2012-09...
End of programming mode Beeeep 3. Hold the B master medium in front of the outer door knob for approx. 1 s. If no master medium is held up within 10 seconds, programming mode 1 x long ends automatically. k1evo805en-2012-09 Kaba digital cylinder...
Page 35
End of programming mode Beeeep 3. Hold the A master medium in front of the outer door knob for approx. 1 s. If no master medium is held up within 10 seconds, programming mode 1 x long ends automatically. Kaba digital cylinder k1evo805en-2012-09...
15 s, or with a B structure do Beep the same with the master B 15 s 2 x short medium (after 10 s the authorisations are deleted and after 15 s all masters are 15 s deleted). k1evo805en-2012-09 Kaba digital cylinder...
Programming Programming with programmer and software Using the Kaba evolo Manager software, all access authorisations can be allocated clearly on the computer screen. Subsequently, the data from the software must be downloaded to the programmer. From the programmer, the data must then be transferred to the digital cylinders.
Page 38
ENTER key. 4. The configuration of the digital cylinder will be read out and confirmed. The traceback and the configurations must be transferred to the higher-level software so they can be evaluated by the programmer. k1evo805en-2012-09 Kaba digital cylinder...
8.1.1 Maintenance interval for digital cylinder and digital anti-panic cylinder Components Measures Frequency Check on the components and function 1 month Kaba anti-panic digital cylinder Repair of the cam's spring mechanism required 10 years Function check as specified in user manual for 12 months All types...
Page 40
4. Press down the lever handle, which should open the latch, the bar and the door. 5. Let go of the inside door knob – the inside knob should return to the neutral area (5 – 7 o'clock position) automatically. k1evo805en-2012-09 Kaba digital cylinder...
Using the programmer, the traceback of the last 2000 events can be read out, as long as the function has not previously been deactivated in the software Kaba evolo Manager. Detailed information on programming the Kaba digital cylinder can be found in the user manuals for the programmer and the Kaba evolo Manager software.
4. Set the clock using the programmer. For access authorisations with time settings and CardLink, always set the clock precisely after emergency opening. The separate user manual for the programmer contains a detailed description of emergency opening. k1evo805en-2012-09 Kaba digital cylinder...
2 x short contacts (on the back) become visible. 3. Hold up an authorised medium. 4. Within 3 seconds, short circuit the INI reset contacts with an electrically-conductive pair of tweezers (3 seconds). The INI reset is implemented. Kaba digital cylinder k1evo805en-2012-09...
Check the digital authorisation cylinder's clock using the programmer In a Whitelist 1 x long 1 x green Clock malfunction Check the digital authorisation with access 1 x short cylinder's clock using the 1 x long programmer k1evo805en-2012-09 Kaba digital cylinder...
Kaba evolo Manager Kaba evolo Manager is software to configure and manage various types of digital cylinders in one or more locking systems. Configuring Configuring is modifying settings in the digital cylinders.
Page 46
User manual Notes k1evo805en-2012-09 Kaba digital cylinder...
Page 47
User manual Glossary Kaba digital cylinder k1evo805en-2012-09...
Need help?
Do you have a question about the 1435MID and is the answer not in the manual?
Questions and answers