Page 2
• FEATURES • 10 Codes (Manager and 9 User) • Time Delay (99 min delay, 19 open) • Code length (6 to 9) • PC programmable Software • Fully Key Pad configurable • Audit (63 first in first out, non-erasable)
Page 5
• Exit Pre-set mode Step 1) Press and Hold ‘0’ key until unit signals twice. Step 2) Enter the default Manger Code 5-5-5-5-5-5. • Lock will open and is now in the Setup and Test mode.
Page 6
• Select Code Length • Example: How to change code length from 6 to 9 digits • Enter: 5-5-5-5-5-5 Hold down the last digit until the lock signals twice and the LED stays on. • PRESS ‘8’ key. • PRESS ‘9’ (the desired code length), then PRESS ‘0’ •...
Page 7
• Select Code Length • Example: How to change code length from 9 to 6 digits • Enter: 5-5-5-5-5-5-5-5-5 Hold down the last digit until the lock signals twice and the LED stays on. • PRESS ‘8’ key. • PRESS ‘6’ (the desired code length), then PRESS ‘0’ •...
Page 8
• Install Users (1,2, & 9) • Enter: 5-5-5-5-5-5 Hold down the last digit until the lock signals twice and the LED stays on. • PRESS ‘1’ key. • Select User ID: ‘1’ • Enter user code: 1-1-1-1-1-1; re-enter code 1-1-1-1-1-1 •...
Page 9
• Install Users (1,2, & 9) • Enter: 5-5-5-5-5-5 Hold down the last digit until the lock signals twice and the LED stays on. • PRESS ‘1’ key. • Select User ID: ‘2’ • Enter user code: 2-2-2-2-2-2; re-enter code 2-2-2-2-2-2 •...
Page 10
• Install Users (1,2, & 9) • Enter: 5-5-5-5-5-5 Hold down the last digit until the lock signals twice and the LED stays on. • PRESS ‘1’ key. • Select User ID: ‘9’ (User 9 will later be enabled to override time delay) •...
Page 12
Added Lock Features • Enter: 5-5-5-5-5-5 Hold down the last digit until the lock signals twice and the LED stays on. • PRESS ‘8’ key. • Enter ‘0’ (this will maintain the current code length) • Enter Option ‘5’ (Time Delay Override and Silent Alarm) •...
Page 13
• Finalizing and Exiting Setup Once the Manager changes his or her code, the configuration is frozen. Special Function #8 is no longer available. Un-enrolled Users are blocked and can not be added later. Also, the lock’s operational mode can no longer be changed. To change Manger code: •...
Page 14
The lock is now configured as follows: • Users 1, 2, and 9 are active. • Users 3, 4, 5, 6, 7, and 8 are blocked and can not be enrolled later. • Time delay Override is Enabled. (User 9) •...
Page 15
How to Changing Time Values We will set the following time values: Delay 1 minute Open 1 minute • Time Delay Setup • Enter Master code ‘1-2-3-4-5-6’ Hold down the last digit until the lock signals twice and the LED stays on. •...
Page 16
The lock is now configured as follows: • Users 1, 2, and 9 are active. • Users 3, 4, 5, 6, 7, and 8 are blocked and can not be enrolled later. • Time delay Override is Enabled. (User 9) •...
Page 17
To start the delay period, enter either the Manager or a User code. To override the delay Enter User # 9’s code. Note: If Time Delay is active it can only be deactivated or delay value decreased in the Open Period. Selecting ‘0000’ deactivates the Time Delay Feature.
Page 18
This concludes the lock setup with via the key pad. Thank You...