5

Overview of authorizations

The authorizations of individual operators are as follows:
Code
Operator ID
designation
-
Inspection key
00
Master code
01..30
User codes
95
Courier code
-
Assembler code

Table 2: Authorizations

6

Overview of the programming commands

Action
Changing own code
Reading out audit
Activating + deactivating OD/OST
Activating user
Blocking + releasing user
Deleting user
Code status query
Activating + deactivating double code
Activating + deactivating silent alarm
Acknowledging the take-off contact message
Resetting the lock
Reassignment of the master code

Table 3: Programming commands

Version 2013-08-10
Page 32 of 48
Authorization
-
Opening without OD/OST and without guard time
-
Assigning of a new master code
-
Resetting the lock
-
Changing the lock configurations using software without
knowing the master code or changing it.
-
Opening, if necessary, with silent alarm
-
Changing of the own code
-
Activating, blocking, releasing, deleting user and courier, with
activated double code as well
-
Activating / deactivating double code
-
Programming / deleting OD/OST
-
Neutralising the take-off contact
-
Reading out audit
-
Activating, deactivating silent alarm
-
Access via PC software
-
Opening, if necessary, with silent alarm
-
Changing of the own code
-
Opening without OD/OST, if necessary, with silent alarm
-
Changing of the own code
-
Opening
-
Valid only until the real start-up of the lock,
NOT A REAL CODE, not suitable for permanent use
Operating instructions 82132/3xxx CB 30
Command Authorization
P
each
P1
P2
P3
P4
Master
P5
P6
P7
P8
P9
P0
Key
P