DSO26 User Manual
SYSTEM SUB-MENU
System Status
Displays unit information including software version and temperature.
Curr. Temp. = current temperature in degrees Celsius.
Max1. Temp. = maximum temperature this session.
Max2. Temp. = maximum temperature ever reached.
LCD Contrast
Adjusts the LCD contrast from 0 to 100.
LED Brightness
Adjusts the LED brightness from 1 to 15.
Temperature Alarm
Sets a temperature warning between 20 and 80°C. The default screen will flash 'ALARM.
Temp = n°C' when the specified temperature is reached. (N.B. the warning does not affect
the units' performance in any respect.)
Wake-up Time
Sets how the unit starts up with one of the following options.
0 to 60 seconds: Waits the specified time before unit wakes up.
Mute hold: Turns on and holds all output mutes when turned on.
(N.B. Wake-up is a slow ramp in level for about 5 seconds.)
Output Meters
Selects whether the output meters are pre or post mute. If the meters are set to read pre-
mute, they will still show the level, even if the channel has been muted.
Filter Q or BW
Selects whether 'Q' or Bandwidth is displayed in the parametric screens.
Delay Time/Distance
Selects whether delay is displayed in milliseconds, metres, or feet.