Preparation
1.
Prepare area for installation by removing all items from under the sink. Locate and turn off cold water
supply and open faucet to relieve any remaining pressure.
2.
Look at typical undersink installation diagram in Figure 6. Determine appropriate location for DWS system,
bladder tank, feed water connection, drain connection and air gap faucet for your specific application.
3.
Locate and close the cold water shut-off valve.
4.
Follow the cold water line from shut-off valve to the existing faucet and unscrew the threaded connection.
Insert feed supply valve between cold water line and existing connection. Refer to Figure 4 and follow the
assembly sequence shown for attaching valve to the existing cold water line. When installation of the valve
is complete, check for leaks as follows:
a.
Close feed supply valve.
b.
Open cold water supply valve and check for leaks around feed supply valve fittings. Tighten
if necessary.
Note: To be certain of the cold line; turn on the hot water, allow water to run until pipe becomes warm. Then
attach fitting to the cold water line. If you run hot water through your system it will damage the membrane.