SpectraPure MaxCap D1 Installation And Operating Manual

SpectraPure MaxCap D1 Installation And Operating Manual

Advertisement

The M
C
D1 System
®
AX
AP
SpectraPure, Inc.
Revolutionary MAXCAP
DI cartridge has 3.5 times
®
®
more capacity than any other Mixed-Bed or Hi-Silica removal deionizing
cartridge. When placed upstream of your existing DI cartridge, the life of
your downstream DI cartridge will increase significantly! This incredible
breakthrough in DI cartridge technology will reduce your costs to produce
DI water by over 50%.
INSTALLATION AND OPERATING
MANUAL
Warning: SpectraPure does not recommend
drinking deionized water.
REV3 08-24-2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MaxCap D1 and is the answer not in the manual?

Questions and answers

Summary of Contents for SpectraPure MaxCap D1

  • Page 1 When placed upstream of your existing DI cartridge, the life of your downstream DI cartridge will increase significantly! This incredible breakthrough in DI cartridge technology will reduce your costs to produce DI water by over 50%. INSTALLATION AND OPERATING MANUAL Warning: SpectraPure does not recommend drinking deionized water. REV3 08-24-2015...
  • Page 2 ALL RIGHTS RESERVED No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written permission of SpectraPure Inc. SpectraPure Inc.
  • Page 3: Frequently Asked Questions

    Yes. Any system using standard 2.5" x 10" DI cartridges can benefit. DO I NEED TO BUY A NEW SYSTEM TO USE IT? REPLACEMENT COMPONENTS NAME MODEL # MaxCap DI-MC-10 ® SpectraPure Inc . ® Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: sales@spectrapure.com Visit us on the web www.spectrapure.com...
  • Page 4: Installation

    SpectraPure ® INSTALLATION ® Replace your original DI cartridge with the new MaxCap D1 cartridge. ® Cut the tubing leading to the MaxCap DI cartridge and insert the“IN” tee of the TDS meter. ® Cut the Tubing leaving the MaxCap DI cartridge and insert the “OUT”...
  • Page 5 5-STAGE SP2000 RO/DI WITH MaxCap INCLUDED ™ ® NOTE: In place of the optional purity monitor, we recommend the COM-100 by HM Digital™. SpectraPure Inc . ® Fax 480.894.6109 Fax us toll-free 1.877.527.7873 E-mail: sales@spectrapure.com Visit us on the web www.spectrapure.com...
  • Page 6: Specifications

    SpectraPure ® TDS METER SPECIFICATIONS RANGE: 0-9990 ppm RESOLUTION: 1 ppm (0-999 ppm); 10 ppm (1000-9990 ppm, indicated by a blinking “x10” image ACCURACY: Plus or minus 2% full scale PROBE: 1/4" sensor with 24" (60cm) cables FITTINGS: Standard with 1/4" John Guest T-Fittings (also available with 3/8"...
  • Page 7: Terms And Conditions

    10 days. Returns other than warranty claims may be subject to 20% restocking fee. 8. SpectraPure, Inc. cannot be held liable for damage or loss to a shipment by a freight carrier. Check shipment for damage before acceptance or note on freight bill subject to inspection for concealed damage.
  • Page 8: Installation

    ® and workmanship for a period of three years from the date of receipt. SpectraPure’s liability under this warranty shall be limited to repairing or replacing at SpectraPure’s option, without charge, F.O.B.