Kenwood CK 305 G Instructions For Use - Installation Advice page 39

Gas cooker
Table of Contents

Advertisement

Fig. 9.10
REGULATION OF AIR SUPPLY TO
OVEN AND GRILL BURNERS
Q
P
Using a cross-head screwdriver, slacken
the screw "Q" securing the air flow
regulation collar "P" (figs. 9.10 and 9.11)
and turn the collar forward or backward
to increase or reduce the air aperture
in accordance with gas type and the
indications in the 'Table for the choice of
the injectors'.
Light the burners and check the flames.
Fig. 9.11
39