Gas Connection - Kenwood CK 305 G Instructions For Use - Installation Advice

Gas cooker
Table of Contents

Advertisement

Gas Connection

GB
Cat: II 2H3+
The gas supply must use the nearest gas inlet pipe which is located at the left or the right
hand side at the rear of the appliance (fig. 9.1).
The hose should also be connected in such away that it does not touch the floor.
To screw the connecting tube operate with two spanners (fig. 9.2).
The unused end inlet pipe must be closed with the plug interposing the gasket.
After connecting to the mains, check that the coupling are correctly sealed, using
soapy solution, but never a flame.
Fitting the 1/2" BSP
(male) connector
Gasket
The male
connector is
already
fitted on the left
or right inlet pipe
Left gas
inlet pipe
1/2" BSP (male)
Right gas
inlet pipe
Fig. 9.1
Plug
Fitting the plug on the
inlet pipe terminal not used
Cooker manifold
(Right or left
inlet pipe)
Manifold
male pipe fitting
1/2" G cylindrical
Gasket (#)
(ISO 228-1) male
Plug (#)
1/2" G cylindrical
(ISO 228-1) female
(#) Already fitted on the
right or left inlet pipe
Fig. 9.2