4.2 Rear control panel (Fig. 2)
*
I1: Off/On switch
Turns on the electric power to the welder.
It has two positions, "O" off, and "I" on.
WARNING
*
With the I1 switch in the "I" on position, the welder is
operational.
*
The welder is connected to the mains supply even if the I1
switch is in the "O" position, and therefore there are elec-
trically live parts inside it. Carefully follow the instruc-
tions given in this manual.
*
1 :
Supply cable.
*
F1 : Pressure adjustment knob
* P1 : Filter unit air connection 1/4 " coupling
* F :
Air filter unit

4.3 Technical characteristics

Power supply voltage
(50/60 Hz)
Delayed fuse
Rated power
Cutting current
(x=60%)
(x=100%)
Cutting voltage
(x=60%)
No-load voltage
Pilot arc current
Gas type
Operating pressure
Flow rate
Torch to be used
Protection class
Insulation class
Construction regulations
Dimensions (LXPXH)
Generator weight
Above data are referred to environment al 40°C
Fig.2
G 60
G90
3x400 V (440V)
3x400V
16 A
32 A
8.32 kW
11.98 kW
60 A
90 A
50 A
70 A
124 V
116 V
260 V
265 V
22 A
22 A
AIR
AIR
5 bar
5 bar
180 l/min
180 l/min
PLASMA torch 81.20.037
IP23C
IP23C
H
H
EN60974-1
EN60974-1
EN60974-10
EN60974-10
180x430x300 215x596.5x406
mm
mm
19 Kg
25 Kg

5.0 TRANSPORT - UNLOADING

Never underestimate the weight of the equipment,
(see technical characteristics).
Never make the cargo pass or leave it suspended
over people or things.
Neither let the equipment or the single unit fall,
nor put it down with force.
Once it has been removed from the packing, the power
source is supplied with an extendible belt which can be
used to move it in the hand or on the shoulder.

6.0 INSTALLATION

Choose an adequate installation area by following
the criteria provided in Section "1.0 SAFETY" and
"2.0 ELECTROMAGNETIC COMPATIBILITY (EMC)".
Do not position the power source and the equip-
ment on surfaces with inclination exceeding 10°
with respect to the horizontal plane.
Protect the installation from heavy rain and sun.

6.1 Electric connection to the supply mains

The equipment is provided with a single electric connection with
a 5m cable positioned in the rear part of the power source.
Size table of the power source input cables and fuses:
Power source
Rated voltage
Voltage range
Delayed fuses
Power supply cable
Power source
Rated voltage
Voltage range
Delayed fuses
Power supply cable
WARNING
* The electrical system must be made by skilled technicians
with the specific professional and technical qualifications
and in compliance with the regulations in force in the
country where the equipment is installed.
* The welding power source supply cable is provided with a
yellow/green wire that must ALWAYS be earthed. This yel-
low/green wire must NEVER be used with other voltage
conductors.
* Verity the existence of the earthing in the used plant and
the good condition of the socket/s
* lnstall only plugs that are homologated according to the
safety regulations.
GENESIS 60
400 V ±15%
440 V ±15%
340 - 460 V
374 - 506 V
16 A 500 V
16 A 500 V
4x4 mm2
4x4 mm2
GENESIS 90
400 V ±15%
340 - 460 V
32 A 500 V
4x6 mm2