System > Port Settings - D-Link SmartPro DGS-1500-20 User Manual

Smartpro switch
Hide thumbs Also See for SmartPro DGS-1500-20:
Table of Contents

Advertisement

5 Configuration
New Password: Enter the new password that you wish to set on the Switch to authenticate users attempting
to access Administrator Level privileges on the Switch. The user may set a password of up to 20 characters.
Confirm Password: Confirm the new password entered above. Entering a different password here from the
one set in the New Local Enabled field will result in a fail message.
System > Port Settings
In the Port Setting page, the status of all ports can be monitored and adjusted for optimum configuration. By
selecting a range of ports (From Port and To Port), the Speed can be set for all selected ports by clicking
Apply. Press the Refresh button to view the latest information.
Speed: Gigabit Fiber connections can operate in 1000M Full Force Mode, Auto Mode or Disabled. Copper
connections can operate in Forced Mode settings (1000M Full, 100M Full, 100M Half, 10M Full, 10M Half),
Auto, or Disabled. The default setting for all ports is Auto.
MDI/MDIX:
A medium dependent interface (MDI) port is an Ethernet port connection typically used on the Network
Interface Card (NIC) or Integrated NIC port on a PC. Switches and hubs usually use Medium dependent
interface crossover (MDIX) interface. When connecting the Switch to end stations, user have to use
straight through Ethernet cables to make sure the Tx/Rx pairs match up properly. When connecting the
Switch to other networking devices, a crossover cable must be used.
This switch provides a configurable MDI/MDIX function for users. The switches can be set as an MDI port in
order to connect to other hubs or switches without an Ethernet crossover cable.
Auto MDI/MDIX is designed on the switch to detect if the connection is backwards, and automatically
chooses MDI or MDIX to properly match the connection. The default setting is "Auto" MDI/MDIX.
Flow Control: You can enable this function to mitigate the traffic congestion. Ports configured for full-duplex
use 802.3x flow control, half-duplex ports use backpressure flow control. The default setting is Disabled.
Figure 5.20 – System > Port Settings
NOTE: Be sure to adjust port speed settings
appropriately after changing the connected cable
media types.
2
7
2
7
D-Link Web Smart Switch User Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartpro dgs-1500-28Smartpro dgs-1500-52

Table of Contents