RESIDENTIAL SMALL
:
A residential community (more than four homes) having one or more gated entrances/exits, allowing vehicle access trumps security concerns
RESIDENTIAL LARGE:
Business site where security (gate closed) is important
COMMERCIAL:
Large business site where security is required
INDUSTRIAL:
Setting
Secure – Manual switch
setting
Quick Close switch setting
AC Fail Open switch setting
Low Battery switch setting
Anti-Tail switch setting
Bipart Delay switch setting
Aux Relay Out – Open
Limit Switch
Aux Relay Out – Close
Limit Switch
Aux Relay Out – Gate
Motion
Aux Relay Out –
Pre-Motion Delay
(Expansion Board Inputs)
Aux Relay Out – Power
Aux Relay Out – Tamper
(Slide Gates Only)
Cycle Quantity Feedback
Fire Dept Open input
Heater Option
One to four residential homes sharing a gated entrance/exit, allowing vehicle access trumps security concerns
RESIDENTIAL SMALL
Set to MANUAL. If a fault occurs,
residents can manually move gate.
Normally set to OFF. Normal gate
close (timer or control).
Normally set to BATT. Run on
battery if AC power fails.
Normally set to OPEN. If powered
from battery and battery is low,
gate stays open.
Normally set to OFF. CLOSE EYES/
Interrupt loop reverses a closing
gate.
For DUAL-GATE site, set to ON for
gate that delays upon opening
Typically not required.
Typically not required.
Attach alert signal (audible or
visual alert system)
Attach alert signal (audible or
visual alert system)
Attach visual alert to know when
system is charging batteries (i.e.
not running on batteries)
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
being pushed off of close limit
Use during servicing only to
determine operator cycles
Typically not required.
Suggested use if outside
temperature remain below
0°F (-20°C).
RESIDENTIAL LARGE
Set to MANUAL. If a fault occurs,
residents can manually move gate.
Normally set to OFF. Normal gate
close (timer or control).
Normally set to BATT. For local
jurisdiction requirement, set to
OPEN so that gate immediately
opens upon AC power fail.
Normally set to OPEN. If powered
from battery and battery is low,
gate stays open.
Normally set to OFF. CLOSE EYES/
Interrupt loop reverses a closing
gate.
For DUAL-GATE site, set to ON for
gate that delays upon opening
Use with SAMS (Sequence Access
Management System)
Typically not required.
Attach alert signal (audible or
visual alert system)
Attach alert signal (audible or
visual alert system)
Attach visual alert to know when
system is charging batteries (i.e.
not running on batteries)
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
being pushed off of close limit
Use during servicing only to
determine operator cycles
Connect emergency access system
(Knox box switch, SOS system, etc.)
Suggested use if outside
temperature remain below
0°F (-20°C).
32
GATE OPERATOR SETUP EXAMPLES
COMMERCIAL
Set to SECURE. If a fault occurs, use
disconnect and manually move
gate.
Normally set to OFF. Normal gate
close (timer or control).
Normally set to BATT. Run on
battery if AC power fails.
Normally set to CLOSE. If powered
from battery and battery is low,
gate stays close.
Set to ON. In attempt to prevent
vehicle tail-gating, CLOSE EYES/
Interrupt loop pauses a closing
gate.
For DUAL-GATE site, set to ON for
gate that delays upon opening
1) Use with SAMS (Sequence Access
Management System)
2) Connect "Gate Open" indicator
(e.g. light)
Connect "Gate Close/Secure"
indicator (e.g. light)
Attach alert signal (audible or
visual alert system)
Attach alert signal (audible or
visual alert system)
Attach visual alert to know when
system is charging batteries (i.e.
not running on batteries)
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
being pushed off of close limit
Use during servicing only to
determine operator cycles
Typically not required.
Suggested use if outside
temperature remain below
0°F (-20°C).
INDUSTRIAL
Set to SECURE. If a fault occurs, use
disconnect and manually move
gate.
Set to ON, so that gate closes
immediately after vehicle passes
the CLOSE EYES/Interrupt loop.
Normally set to BATT. Run on
battery if AC power fails.
Normally set to CLOSE. If powered
from battery and battery is low,
gate stays close.
Set to ON. In attempt to prevent
vehicle tail-gating, CLOSE EYES/
Interrupt loop pauses a closing
gate.
For DUAL-GATE site, set to ON for
gate that delays upon opening
1) Use with SAMS (Sequence Access
Management System)
2) Connect "Gate Open" indicator
(e.g. light)
Connect "Gate Close/Secure"
indicator (e.g. light)
Attach alert signal (audible or
visual alert system)
Attach alert signal (audible or
visual alert system)
Attach visual alert to know when
system is charging batteries (i.e.
not running on batteries)
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
being pushed off of close limit
Use during servicing only to
determine operator cycles
Typically not required.
Suggested use if outside
temperature remain below
0°F (-20°C).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Liftmaster csl24vh

Table of Contents