TROUBLESHOOTING

CONTROL BOARD LEDS

The control board is equipped with many LEDs that have a variety of functions. The control board LEDs indicate the status of the operator, assist with programming, and
diagnose potential problems with the operator.
NOTE: When cycling or disconnecting power (ac/dc) to the control board, it is recommended that you unplug the J15 plug.
STATUS LEDS
LIMIT SETUP LEDS
SET OPEN
SET CLOSE
LED
LED
BLINKING
BLINKING
OFF
OFF
BLINKING
BLINKING
BLINKING
ON
ON
BLINKING
ON
ON
LIMIT SETUP LEDS
OPERATOR MODE
EXPLANATION
NORMAL MODE
Limits are not set.
NORMAL MODE
Limits are set.
LIMIT SETTING MODE
Limits are not set.
LIMIT SETTING MODE
Open limit is not set.
LIMIT SETTING MODE
Close limit is not set.
LIMIT SETTING MODE
Limits are set.
GREEN XMITTER LED
GREEN XMITTER LED
XMITTER LED
EXPLANATION
OFF
No remote control activity, normal operation.
ON
Programming mode active.
FAST
Recognized remote control signal.
FASTER
Unrecognized remote control signal.
FASTEST
Remote controls are being erased.
34
CONTROL BOARD LEDS
DIAGNOSTIC CODES LEDS
INPUT LEDS